| Literature DB >> 19462376 |
Madussar A Ahmad1, Leela C Biant, Rene Tayar, Paul R Thomas, Richard E Field.
Abstract
Acetabular component extraction following intra-pelvic migration of a total hip replacement can be hazardous to pelvic tissues, vessels and organs. Acetabular component removal is usually performed using an abdominal retroperitoneal approach. We describe a closed reduction of the acetabular component using a traction/manipulation technique. This manoeuvre can be used in cases of intra-pelvic acetabular component migration where the surface contour of the acetabular component is uncomplicated and an interposition membrane separates the implant from adjacent intra-pelvic structures.Mesh:
Year: 2009 PMID: 19462376 DOI: 10.1177/112070000901900215