Literature DB >> 19458994

Transthoracic echocardiography guidance of transcatheter atrial septal defect closure in children.

Mahmoud Zaqout1, Bert Suys, Hans De Wilde, Daniel De Wolf.   

Abstract

Transesophageal echocardiography (TEE) guidance is part of interventional closure of secundum atrial septal defect (ASD) in children and adults. However, sometimes TEE is impossible for technical or anatomical reasons. If available, intracardiac echocardiography can be used, but especially in children, transthoracic echocardiography (TTE) can be an easy, safe, and cheap alternative. We report two cases in which TEE was replaced by TTE during percutaneous ASD closure. In the first case VACTERL association with a surgically repaired tracheoesophageal fistula was a relative contraindication to TEE. In the second case, technical failure of the transesophageal probe occurred during the procedure. In both cases the ASD was successfully closed with an atrial septal occluder device under TTE guidance. Using TTE can be sufficient and safe in children with good imaging windows, especially from subcostal views.

Entities:  

Mesh:

Year:  2009        PMID: 19458994     DOI: 10.1007/s00246-009-9456-8

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  9 in total

1.  Transesophageal echocardiographic results of catheter closure of atrial septal defect in children and adults using the Amplatzer device.

Authors:  Z M Hijazi; Q Cao; H T Patel; J Rhodes; K M Hanlon
Journal:  Am J Cardiol       Date:  2000-06-01       Impact factor: 2.778

Review 2.  Closure of secundum atrial septal defects with the Amplatzer septal occluder device: techniques and problems.

Authors:  Richard W Harper; Philip M Mottram; David J McGaw
Journal:  Catheter Cardiovasc Interv       Date:  2002-12       Impact factor: 2.692

Review 3.  Use of intracardiac echocardiography to guide catheter closure of atrial communications.

Authors:  Peter R Koenig; Ra-id Abdulla; Qi-Ling Cao; Ziyad M Hijazi
Journal:  Echocardiography       Date:  2003-11       Impact factor: 1.724

4.  Experience with use of multiplane transesophageal echocardiography to guide closure of atrial septal defects using the amplatzer device.

Authors:  M I Figueroa; D Balaguru; C McClure; C H Kline; W A K Radtke; G S Shirali
Journal:  Pediatr Cardiol       Date:  2002 Jul-Aug       Impact factor: 1.655

5.  Intracardiac echocardiography to guide closure of atrial septal defects in children less than 15 kilograms.

Authors:  Angira Patel; Qi-Ling Cao; Peter R Koenig; Ziyad M Hijazi
Journal:  Catheter Cardiovasc Interv       Date:  2006-08       Impact factor: 2.692

6.  Percutaneous closure with Amplatzer device is a safe and efficient alternative to surgery in adults with large atrial septal defects.

Authors:  J Losay; J Petit; V Lambert; G Esna; X Berthaux; P Brenot; C Angel
Journal:  Am Heart J       Date:  2001-09       Impact factor: 4.749

7.  Transthoracic echocardiographic guidance of transcatheter atrial septal defect closure.

Authors:  Richard E Kardon; Mary C Sokoloski; Daniel S Levi; James S Perry; Douglas J Schneider; Vivekanand Allada; John W Moore
Journal:  Am J Cardiol       Date:  2004-07-15       Impact factor: 2.778

8.  ASD closure with the Amplatzer device.

Authors:  Horacio J Faella; Alberto M Sciegata; José L Alonso; Luis Jmelnitsky
Journal:  J Interv Cardiol       Date:  2003-10       Impact factor: 2.279

9.  Transesophageal echocardiographic guidance of transcatheter closure of atrial septal defect.

Authors:  W E Hellenbrand; J T Fahey; F X McGowan; G G Weltin; C S Kleinman
Journal:  Am J Cardiol       Date:  1990-07-15       Impact factor: 2.778

  9 in total
  11 in total

1.  Transthoracic echocardiographic guidance during transcatheter closure of atrial septal defects in children and adults.

Authors:  Abdullah Erdem; Turkay Sarıtas; Cenap Zeybek; Ilker Kemal Yucel; Nurdan Erol; Halil Demır; Ender Odemıs; Yalim Yalcın; Ahmet Celebı
Journal:  Int J Cardiovasc Imaging       Date:  2011-08-11       Impact factor: 2.357

2.  Catheter interventions in congenital heart disease without regular catheterization laboratory equipment: the chain of hope experience in Rwanda.

Authors:  John Senga; Emmanuel Rusingiza; Joseph Mucumbitsi; Agnès Binagwaho; Bert Suys; Christine Lys; Karlien Carbonez; Caroline Ovaert; Thierry Sluysmans
Journal:  Pediatr Cardiol       Date:  2012-05-27       Impact factor: 1.655

3.  Percutaneous trans-jugular vein closure of atrial septal defect with steerable introducer under echocardiographic guidance.

Authors:  Shaobo Xie; Jian Fang; Chao Yang; Lunchao Ma; Suhua Kuang; Guoliang Lu; Yingyuan Zhang; Shengjie Liao
Journal:  J Thorac Dis       Date:  2015-10       Impact factor: 2.895

4.  Interventional closure of atrial septal defects without fluoroscopy in adult and pediatric patients.

Authors:  Stephan Schubert; Sarah Kainz; Björn Peters; Felix Berger; Peter Ewert
Journal:  Clin Res Cardiol       Date:  2012-03-28       Impact factor: 5.460

5.  Safe and efectivef guidance by intracardiac echocardiography for transcatheter closure in atrial septal defects.

Authors:  Yu Wang; Tao Guo; Guizheng Liang; Ling Zhao; Jiahua Pan; Shumin Li; Baotong Hua; Lijin Pu
Journal:  Int J Clin Exp Med       Date:  2015-05-15

6.  Safe and effective guidance by intracardiac echocardiography for transcatheter closure in atrial septal defects.

Authors:  Jing Zhao; Li Li; Ling Peng
Journal:  Int J Clin Exp Med       Date:  2015-06-15

7.  Transcatheter Closure of Atrial Septal Defect with Amplatzer Device in Children and Adolescents: Short and Midterm results; an Iranian Experience.

Authors:  Mostafa Behjati; Sayed-Jalil Mirhosseini; Saiyed-Habibollah Hosseini; Shahrokh Rajaei
Journal:  Iran J Pediatr       Date:  2011-06       Impact factor: 0.364

8.  Transcatheter Atrial Septal Defect Closure under Transthorasic Echocardiography in Children.

Authors:  Keyhan Sayadpour Zanjani; Aliakbar Zeinaloo; Elaheh Malekan-Rad; Abdolrazagh Kiani; Mohammad-Mehdi Bagheri
Journal:  Iran J Pediatr       Date:  2011-12       Impact factor: 0.364

9.  Percutaneous device closure of atrial septal defect with totally transthoracic echocardiography guide, without x-ray machine.

Authors:  Hua Cao; Qiang Chen; Gui-Can Zhang; Liang-Wan Chen; Zhi-Huang Qiu; Heng Lu
Journal:  Medicine (Baltimore)       Date:  2016-11       Impact factor: 1.889

10.  Safety and efficacy of transthoracic versus transesophageal echocardiography in transcatheter closure of atrial septal defects. Reporting a single center experience from Saudi Arabia.

Authors:  Ahmad S Azhar
Journal:  Saudi Med J       Date:  2016-11       Impact factor: 1.484

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.