Pam Bagley1, Mary Hudson, John Green, Anne Forster, John Young. 1. Division of Physiotherapy and Occupational Therapy, School of Health Studies, University of Bradford, 25 Trinity Road, Bradford, West Yorkshire BD5 0BB, UK. p.j.bagley@bradford.ac.uk
Abstract
OBJECTIVE: To assess the reliability of duration of treatment time measured by physiotherapy staff in early-stage stroke patients. DESIGN: Comparison of physiotherapy staff's recording of treatment sessions and video recording. SETTING:Rehabilitation stroke unit in a general hospital. SUBJECTS:Thirty-nine stroke patients without trunk control or who were unable to stand with an erect trunk without the support of two therapists recruited to a randomized trial evaluating the Oswestry Standing Frame. Twenty-six physiotherapy staff who were involved in patient treatment. MAIN MEASURES: Contemporaneous recording by physiotherapy staff of treatment time (in minutes) compared with video recording. STATISTICAL ANALYSIS: Intraclass correlation with 95% confidence interval and the Bland and Altman method for assessing agreement by calculating the mean difference (standard deviation; 95% confidence interval), reliability coefficient and 95% limits of agreement for the differences between the measurements. RESULTS: The mean duration (standard deviation, SD) of treatment time recorded by physiotherapy staff was 32 (11) minutes compared with 25 (9) minutes as evidenced in the video recording. The mean difference (SD) was -6 (9) minutes (95% confidence interval (CI) -9 to -3). The reliability coefficient was 18 minutes and the 95% limits of agreement were -24 to 12 minutes. Intraclass correlation coefficient for agreement between the two methods was 0.50 (95% CI 0.12 to 0.73). CONCLUSIONS: Physiotherapy staff's recording of duration of treatment time was not reliable and was systematically greater than the video recording.
RCT Entities:
OBJECTIVE: To assess the reliability of duration of treatment time measured by physiotherapy staff in early-stage strokepatients. DESIGN: Comparison of physiotherapy staff's recording of treatment sessions and video recording. SETTING: Rehabilitation stroke unit in a general hospital. SUBJECTS: Thirty-nine strokepatients without trunk control or who were unable to stand with an erect trunk without the support of two therapists recruited to a randomized trial evaluating the Oswestry Standing Frame. Twenty-six physiotherapy staff who were involved in patient treatment. MAIN MEASURES: Contemporaneous recording by physiotherapy staff of treatment time (in minutes) compared with video recording. STATISTICAL ANALYSIS: Intraclass correlation with 95% confidence interval and the Bland and Altman method for assessing agreement by calculating the mean difference (standard deviation; 95% confidence interval), reliability coefficient and 95% limits of agreement for the differences between the measurements. RESULTS: The mean duration (standard deviation, SD) of treatment time recorded by physiotherapy staff was 32 (11) minutes compared with 25 (9) minutes as evidenced in the video recording. The mean difference (SD) was -6 (9) minutes (95% confidence interval (CI) -9 to -3). The reliability coefficient was 18 minutes and the 95% limits of agreement were -24 to 12 minutes. Intraclass correlation coefficient for agreement between the two methods was 0.50 (95% CI 0.12 to 0.73). CONCLUSIONS: Physiotherapy staff's recording of duration of treatment time was not reliable and was systematically greater than the video recording.
Authors: Carol L Richards; Francine Malouin; Sylvie Nadeau; Joyce Fung; Line D'Amours; Claire Perez; Anne Durand Journal: Physiother Can Date: 2019 Impact factor: 1.037
Authors: Carol L Richards; Francine Malouin; Sylvie Nadeau; Joyce Fung; Line D'Amours; Claire Perez; Anne Durand Journal: Physiother Can Date: 2018 Impact factor: 1.037
Authors: Louise A Connell; Naoimh E McMahon; Lisa A Simpson; Caroline L Watkins; Janice J Eng Journal: Arch Phys Med Rehabil Date: 2014-06-16 Impact factor: 3.966