Literature DB >> 19455479

The reliability of VO2(peak) determination in healthy females during an incremental arm ergometry test.

A S Leicht1, R M Sealey, W H Sinclair.   

Abstract

This study examined the reliability of an incremental arm ergometry (AE) protocol during peak aerobic power (VO2(peak)) determination in healthy females. Fifteen females completed two incremental AE tests to exhaustion, seven to eleven days apart, using a mechanically braked arm ergometer. The initial work rate was 16W and increased by 16W every two minutes until exhaustion. Significant differences between tests were determined by repeated measures ANOVA, and paired t-tests or Wilcoxon signed-rank tests, where appropriate. Reliability was determined by intraclass correlation coefficients (ICC), typical error, coefficient of variation (CV) and measurement bias/ratio and 95% limits of agreement (LOA). Peak cardio-respiratory responses were similar between tests, except for tidal volume (1.95 +/-0.47 vs. 1.81 +/- 0.41 L, P<0.05). Reliability for peak variables was moderate to high (ICC=0.659-0.941; CV< or =10%) while LOA were considerable for most variables including VO2(peak) (LOA=0.57 L.min(-1)). Similar peak cardio-respiratory responses, low CV and moderate-high ICC confirmed the reliability of the current incremental AE protocol to be similar to that of prior reported protocols for VO2(peak) determination. Substantial within-participant variability (LOA) for respiratory rate and tidal volume was common during the AE protocol and possibly reflects the influence of respiratory entrainment on reliability that requires further investigation.

Entities:  

Mesh:

Year:  2009        PMID: 19455479     DOI: 10.1055/s-0029-1202351

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  4 in total

1.  Immediate Effects of Smoking on Cardiorespiratory Responses During Dynamic Exercise: Arm Vs. Leg Ergometry.

Authors:  Chien-Liang Chen; Jing-Shia Tang; Ping-Chia Li; Pi-Ling Chou
Journal:  Front Physiol       Date:  2015-12-10       Impact factor: 4.566

2.  Assessment of peak oxygen uptake during handcycling: Test-retest reliability and comparison of a ramp-incremented and perceptually-regulated exercise test.

Authors:  Michael J Hutchinson; Thomas A W Paulson; Roger Eston; Victoria L Goosey-Tolfrey
Journal:  PLoS One       Date:  2017-07-13       Impact factor: 3.240

3.  Comparison of Peak Oxygen Uptake and Test-Retest Reliability of Physiological Parameters between Closed-End and Incremental Upper-Body Poling Tests.

Authors:  Julia K Baumgart; Knut Skovereng; Øyvind Sandbakk
Journal:  Front Physiol       Date:  2017-10-30       Impact factor: 4.566

4.  Test-Retest Reliability of Physiological Variables During Submaximal Seated Upper-Body Poling in Able-Bodied Participants.

Authors:  Marlou Ettema; Berit Brurok; Julia Kathrin Baumgart
Journal:  Front Physiol       Date:  2021-11-30       Impact factor: 4.566

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.