Literature DB >> 19455042

Skin impedance correlates to sedation grade, plasma propofol concentrations and bispectral index during a target-controlled infusion of propofol.

Michael Winterhalter1, Sinikka Münte, Peter Taschenbrecker, Hartmut Hecker, Christian Weilbach, Alexander W Osthaus, Matthias Gross, Siegfried Piepenbrock, Niels Rahe-Meyer.   

Abstract

BACKGROUND AND
OBJECTIVE: Sympathetic activity, measured as changes in electrical skin impedance, may be used to assess the adequacy of general anaesthesia. The aim of this prospective study was to evaluate electrical skin impedance in comparison with bispectral index values and the Observer's Assessment of Alertness and Sedation (OAAS) scale during propofol infusion.
METHODS: Electrical skin impedance was measured with an electrosympathicograph. In 22 patients and eight healthy volunteers, anaesthesia was induced and maintained with propofol that was administered via a target-controlled infusion pump at increasing plasma concentrations. Bispectral index, electrosympathicograph and OAAS values were compared at six successive predicted target plasma concentrations (T 1-6: 0, 1.3, 1.7, 2.0, 2.4 and 2.8 microg ml(-1)).
RESULTS: The changes in the electrical skin impedance measured with the assistance of the electrosympathicograph correlated with the changes in bispectral index values at each measurement time point and during the whole course (P < 0.0001), with the target plasma propofol concentrations (P < 0.0001), and with the OAAS scale (P < 0.0001).
CONCLUSION: The observed correlations between electrical skin impedance, predicted plasma concentrations of propofol and OAAS scale appear to justify further investigation of skin impedance as a depth of anaesthesia monitor.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19455042     DOI: 10.1097/EJA.0b013e328329b149

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  3 in total

1.  Recent advance in patient monitoring.

Authors:  Tomoki Nishiyama
Journal:  Korean J Anesthesiol       Date:  2010-09-20

2.  Prospective study comparing skin impedance with EEG parameters during the induction of anaesthesia with fentanyl and etomidate.

Authors:  Michael Winterhalter; S Münte; M Gerhard; O Danzeisen; T Jüttner; E Monaca; L Hoy; N Rahe-Meyer; P Kienbaum
Journal:  Eur J Med Res       Date:  2010-02-26       Impact factor: 2.175

3.  Can changes in skin impedance be used to monitor sedation after midazolam and during recovery from anesthesia?

Authors:  A Kurzová; L Hess; J Slíva; J Málek
Journal:  Physiol Res       Date:  2021-03-08       Impact factor: 1.881

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.