Literature DB >> 19454535

Development of a new measurement method for serum calcium with chlorophosphonazo-III.

Eisaku Hokazono1, Susumu Osawa, Tomota Nakano, Yukari Kawamoto, Yuji Oguchi, Taeko Hotta, Yuzo Kayamori, Dongchon Kang, Yuichiro Cho, Kiyoko Shiba, Kenji Sato.   

Abstract

BACKGROUND: Although serum calcium has been measured using the o-cresolphthalein complexone (oCPC) method in the clinical laboratory, this method still has some problems regarding linearity and reagent stability. We developed a new measurement procedure using chlorophosphonazo-III (CPZ-III: 2,7-bis (4-chloro-2-phosphonophenylazo) -1,8- dihydroxy-3, 6-naphthalenedisulphonic acid, disodium salt) as a chelator with an acid medium for serum calcium measurement. The present method showed better linearity and reagent stability compared with the oCPC method.
METHODS: Characteristics were studied in optimized conditions measuring wavelength by absorption spectra analysis, and interference of protein and metals with Mg(2+), Fe(2+), Cu(2+) and Zn(2+). The method was applied to an automated analyser (7170; Hitachi High Technologies Corp). The measurement performance was evaluated for accuracy, precision, recovery rate, linearity and reagent stability with a comparison study against atomic absorption spectrophotometry (AAS).
RESULTS: The within-run and between-run variations (coefficient of variation [CV]) were 0.92-1.01% and 0.75-1.43%, respectively. The linearity was 0-7.0 mmol/L. The comparison study obtained y = 1.002x (AAS) - 0.10, Sy/x = 0.18 mmol/L, n = 50. Reagent stability was at least 20 d at 4 degrees C without daily calibration.
CONCLUSION: The new calcium measurement method in serum was demonstrated to have reliable and acceptable performances as a routine test in clinical laboratory.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19454535     DOI: 10.1258/acb.2009.008099

Source DB:  PubMed          Journal:  Ann Clin Biochem        ISSN: 0004-5632            Impact factor:   2.057


  5 in total

1.  Longitudinal Assessment of Calcium and Magnesium Levels in Women with Preeclampsia.

Authors:  Nisha Wadhwani; Kamini Dangat; Karuna Randhir; Anupam Poddar; Prachi Joshi; Hemlata Pisal; Vrushali Kadam; Ravleen Bakshi; Nomita Chandhiok; Sanjay Lalwani; Savita Mehendale; Girija Wagh; Sanjay Gupte; Harshpal Singh Sachdev; Caroline Fall; Sadhana Joshi
Journal:  Biol Trace Elem Res       Date:  2022-10-10       Impact factor: 4.081

2.  Chronic toxicity study of neosaxitoxin in rats.

Authors:  Ramiro J Zepeda; Manila Candiracci; Nicolas Lobos; Sebastian Lux; Hugo F Miranda
Journal:  Mar Drugs       Date:  2014-09-25       Impact factor: 5.118

3.  A novel fluorescein-bisphosphonate based diagnostic tool for the detection of hydroxyapatite in both cell and tissue models.

Authors:  Alisia M Sim; Nabil A Rashdan; Lin Cui; Alastair J Moss; Fabio Nudelman; Marc R Dweck; Vicky E MacRae; Alison N Hulme
Journal:  Sci Rep       Date:  2018-11-26       Impact factor: 4.379

4.  Study of interaction of metal ions with methylthymol blue by chemometrics and quantum chemical calculations.

Authors:  Zolaikha Rasouli; Mehdi Irani; Sonia Jafari; Raouf Ghavami
Journal:  Sci Rep       Date:  2021-03-19       Impact factor: 4.379

5.  A Tumor Accelerator Based on Multicomponent Bone Scaffolds and Cancer Cell Homing.

Authors:  Chen-Ji Huang; Pei-Kuan Chou; Zong-Yi Sher; You-Rong Chen; Tan-Yueh Chen; Guo-Chung Dong
Journal:  Polymers (Basel)       Date:  2022-08-16       Impact factor: 4.967

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.