Literature DB >> 19454413

Clinical significance of anastomotic leak in ascending aortic replacement for acute aortic dissection.

Hiroshi Tanaka1, Kenji Okada, Yujiro Kawanishi, Masamichi Matsumori, Yutaka Okita.   

Abstract

'Anastomotic leak' after ascending aortic replacement for acute aortic dissection, which is determined as direct forward blood flow into the false lumen at the distal anastomosis, prevents the false lumen from being thrombosed. The aim of this study is to determine whether the leak influences on residual aortic growth. Between October 1999 and May 2006, 100 patients presenting for acute type A aortic dissection underwent surgery at our institution. Among the population, 34 patients who underwent ascending aortic replacement and have been followed by computed tomography (CT) for over 6 months were reviewed. On the follow-up CT, maximum diameter of aortic arch and descending aorta were measured and the presence of anastomotic leak was determined. The growth rates of aortic arch and descending aorta in patients diagnosed as having anastomotic leak were greater than patients not having leak (P=0.003, P<0.001, respectively). Initial maximum diameter just after ascending aortic replacement was greater in patients with anastomotic leak than without anastomotic leak in aortic arch and descending aorta (P=0.013, P=0.06). Anastomotic leak after ascending aortic replacement for acute type A aortic dissection contributed to remnant aortic growth. More sophisticated method for reapproximation of dissected aorta should be dictated.

Entities:  

Mesh:

Year:  2009        PMID: 19454413     DOI: 10.1510/icvts.2008.201558

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  4 in total

Review 1.  The use of surgical glue in acute type A aortic dissection.

Authors:  Shinichi Suzuki; Munetaka Masuda; Kiyotaka Imoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-11-21

2.  Trans-catheter closure of aortic anastomosis leak after aortic replacement: classifications and techniques.

Authors:  Wenhui Wu; Yutong Ke; Honglei Zhao; Lianjun Huang; Junzhou Pu
Journal:  J Thorac Dis       Date:  2020-09       Impact factor: 2.895

3.  Complete neck vessel preservation using a fenestrated stent graft for the treatment of proximal anastomotic leakage after open frozen elephant trunk graft aortic arch repair.

Authors:  Hikaru Nakagawa; Takao Ohki; Naoki Toya; Eisaku Ito; Tadashi Akiba
Journal:  J Vasc Surg Cases Innov Tech       Date:  2022-01-05

4.  Pseudoaneurysm with a fistula to the right ventricle late after surgical repair of type A aortic dissection in a patient with systemic lupus erythematosus.

Authors:  Akie Shimada; Taira Yamamoto; Daisuke Endo; Kousuke Nishida; Satoshi Matsushita; Tohru Asai; Atsushi Amano
Journal:  J Cardiothorac Surg       Date:  2022-04-27       Impact factor: 1.522