Literature DB >> 19452605

Patent foramen ovale: comparison among diagnostic strategies in cryptogenic stroke and migraine.

Concetta Zito1, Giuseppe Dattilo, Giuseppe Oreto, Gianluca Di Bella, Annalisa Lamari, Raffaella Iudicello, Olimpia Trio, Giuseppe Caracciolo, Sebastiano Coglitore, Francesco Arrigo, Scipione Carerj.   

Abstract

OBJECTIVE: The aim of this study was to compare transthoracic echocardiography (TTE) and transcranial Doppler ultrasonography (TCD) with transesophageal echocardiography (TEE) in order to define the best clinical approach to patent foramen ovale (PFO) detection.
METHODS: In total, 72 consecutive patients (33 men) with a mean age of 49 +/- 13 years were prospectively enrolled. The TEE indication was cryptogenic stroke (36 patients) or migraine (36 patients, 22 with aura). All patients underwent standard TTE, TCD, and TEE examination. For any study, a contrast test was carried on using an agitated saline solution mixed with urea-linked gelatine (Haemaccel), injected as a rapid bolus via a right antecubital vein. A prolonged Valsalva maneuver was performed to improve test sensitivity.
RESULTS: TEE identified a PFO in 65% of the whole population: 56.5% in the migraine cohort and 43.5% in the cryptogenic stroke cohort. TTE was able to detect a PFO in 55% of patients positive at TEE (54% negative predictive value, 100% positive predictive value, 55% sensitivity, and 100% specificity). TCD was able to identify a PFO in 97% of patients positive at TEE (89% negative predictive value, 98% positive predictive value, 94% sensitivity, and 96% specificity).
CONCLUSIONS: In patients with cryptogenic stroke and migraine, there is a fair concordance (k = 0.89) between TCD and TEE in PFO recognition. Accordingly, TCD should be recommended as a simple, noninvasive, and reliable technique, whereas TEE indication should be restricted to selected patients. TTE is a very specific technique, whose major advantage is the ability to detect a large right-to-left shunt, particularly if associated with an atrial septal aneurysm.

Entities:  

Mesh:

Year:  2009        PMID: 19452605     DOI: 10.1111/j.1540-8175.2008.00852.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  18 in total

1.  Interaction of cardiac implantable electronic device and patent foramen ovale in ischemic stroke: A case-only study.

Authors:  Kolade M Agboola; Jin-Moo Lee; Xiaoyan Liu; Eric Novak; Phillip S Cuculich; Daniel H Cooper; Amit Noheria
Journal:  Pacing Clin Electrophysiol       Date:  2019-01-31       Impact factor: 1.976

Review 2.  Migraine and patent foramen ovale.

Authors:  Jessica Ailani
Journal:  Curr Neurol Neurosci Rep       Date:  2014-02       Impact factor: 5.081

3.  The RoPE Score and Right-to-Left Shunt Severity by Transcranial Doppler in the CODICIA Study.

Authors:  Benjamin S Wessler; David M Kent; David E Thaler; Robin Ruthazer; Jennifer S Lutz; Joaquín Serena
Journal:  Cerebrovasc Dis       Date:  2015-07-11       Impact factor: 2.762

4.  Significance of Patent Foramen Ovale in Patients with GOLD Stage II Chronic Obstructive Pulmonary Disease (COPD).

Authors:  Dario Martolini; Rebecca Tanner; Claire Davey; Mehul S Patel; Davide Elia; Helen Purcell; Paolo Palange; Nicholas S Hopkinson; Michael I Polkey
Journal:  Chronic Obstr Pulm Dis       Date:  2014-09-25

Review 5.  Patent foramen ovale: anatomical complexity and long-tunnel morphology related issues.

Authors:  Giampiero Vizzari; Fausto Pizzino; Dianne Zwicke; A Jamil Tajik; Scipione Carerj; Gianluca Di Bella; Antonio Micari; Bijoy K Khandheria; Concetta Zito
Journal:  Am J Cardiovasc Dis       Date:  2021-06-15

Review 6.  Point-of-care echocardiography for the evaluation of right-to-left cardiopulmonary shunts: a narrative review.

Authors:  Tim Montrief; Stephen Alerhand; André Denault; Jeffrey Scott
Journal:  Can J Anaesth       Date:  2020-09-17       Impact factor: 5.063

7.  Walking with Gianluca Di Bella during the development of clinical cardiac imaging.

Authors:  Gianluca Di Bella
Journal:  World J Cardiol       Date:  2010-11-26

8.  Systemic right-to-left shunts, ischemic brain lesions, and persistent migraine activity.

Authors:  Hille Koppen; Inge H Palm-Meinders; Werner H Mess; Ruud W Keunen; Gisela M Terwindt; Lenore J Launer; Mark A van Buchem; Mark C Kruit; Michel D Ferrari
Journal:  Neurology       Date:  2016-03-11       Impact factor: 9.910

9.  Patent foramen ovale in severe obstructive sleep apnea: clinical features and effects of closure.

Authors:  Zarrin F Shaikh; Jay Jaye; Neil Ward; Atul Malhotra; Manuel de Villa; Michael I Polkey; Michael J Mullen; Mary J Morrell
Journal:  Chest       Date:  2013-01       Impact factor: 9.410

Review 10.  Potential Role of Patent Foramen Ovale in Exacerbating Hypoxemia in Chronic Pulmonary Disease.

Authors:  Michael E Layoun; Jamil A Aboulhosn; Jonathan M Tobis
Journal:  Tex Heart Inst J       Date:  2017-06-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.