Unacceptable results with an accepted soft tissue filler: polyacrylamide hydrogel.

Ali Manafi1, Abol-Hasan Emami, Aydin H Pooli, Mohammadali Habibi, Lila Saidian.   

Abstract

BACKGROUND: Polyacrylamide hydrogel, considered a safe and biocompatible soft tissue filler, is widely used in cosmetic procedures. Its use for facial contouring and breast augmentation in Iran has increased dramatically in recent years. Most patients and many doctors are unaware of possible and reported adverse effects related to its administration.
METHODS: This study enrolled 98 patients experiencing unsatisfactory results and complications of polyacrylamide hydrogel. Adverse effects related to gel administration were documented for all the patients. Lab values were requested together with related medical care and surgical treatments, and gel was extracted by incision, milking, and irrigation.
RESULTS: The most common findings at the time of presentation were inflammation (n = 51), asymmetry (n = 31), irregularity (n = 18), infection and abscess formation (n = 11), and gel migration (n = 8). In one patient, severe anaphylactoid reaction was observed 1 week after gel injection, which led to significant complications for the patient. Histologic findings showed granuloma formation (n = 17), fat necrosis (n = 9), and fibrosis (n = 17). Macroscopic gel-related complications resolved after extraction of the injected material, except for skin necrosis and hyperpigmentation, which remained unchanged. For eight patients, the gel could not be extracted by squeezing and irrigation entirely. Three patients experienced gel reaccumulation after seemingly complete removal of the gel.
CONCLUSIONS: A wide range of complications seen among our patients showed that polyacrylamide hydrogel may not be as safe and biocompatible as it was thought previously. Both patients and physicians must be aware of the potential side effects of polyacrylamide hydrogel before gel administration.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19452201     DOI: 10.1007/s00266-009-9359-3

Source DB:  PubMed          Journal:  Aesthetic Plast Surg        ISSN: 0364-216X            Impact factor:   2.326


  10 in total

Review 1.  Safety and Efficiency of Minimally Invasive Buttock Augmentation: A Review.

Authors:  Bishara Atiyeh; Fadi Ghieh; Ahmad Oneisi
Journal:  Aesthetic Plast Surg       Date:  2022-08-23       Impact factor: 2.708

Review 2.  Emerging permanent filler technologies: focus on Aquamid.

Authors:  Paul S Yamauchi
Journal:  Clin Cosmet Investig Dermatol       Date:  2014-10-10

3.  Safety of Copolyamide Filler Injection for Breast Augmentation.

Authors:  Shunichi Nomoto; Keiko Hirakawa; Rei Ogawa
Journal:  Plast Reconstr Surg Glob Open       Date:  2021-02-17

4.  Simple, selective and fast detection of acrylamide based on glutathione S-transferase.

Authors:  Madalina-Petruta Bucur; Bogdan Bucur; Gabriel-Lucian Radu
Journal:  RSC Adv       Date:  2018-07-02       Impact factor: 4.036

5.  Abscess Formation After Tooth Extraction: A Long-Term Complication of Polyacrylamide Hydrogel Filler.

Authors:  Aydan A Kose; Can Ekinci; Atacan E Koçman
Journal:  Cureus       Date:  2022-08-19

6.  Delayed gel indurations as an adverse effect of polyacrylamide filler and its easy treatment.

Authors:  Hossein Kavoussi; Ali Ebrahimi
Journal:  Dermatol Res Pract       Date:  2012-10-09

7.  A Case of Foreign-Body Granuloma of the Glabella due to Polyacrylamide Filler and an Intractable Ulcer after Skin Biopsy: An Immunohistochemical Evaluation of Inflammatory Changes.

Authors:  Kio Park; Fuyuko Nishiwaki; Kenji Kabashima; Yoshiki Miyachi
Journal:  Case Rep Dermatol       Date:  2013-06-20

8.  Nonthrombotic Pulmonary Embolism: A Potential Complication of Polyacrylamide Hydrogel Cosmetic Injection.

Authors:  Faisal Inayat; Ahmad R Cheema; Hafeez Ul Hasan Virk; Daniel J Yoon; Salman Farooq; Abdul Manan
Journal:  Case Rep Med       Date:  2016-01-14

9.  Resolution of Cosmetic Buttock Injection-induced Inflammatory Reaction and Heart Failure after Excision of Filler Material.

Authors:  Chad A Purnell; Julian L Klosowiak; Jennifer E Cheesborough; Eugene Park; Andrew Bandy; Gregory A Dumanian
Journal:  Plast Reconstr Surg Glob Open       Date:  2016-10-04

10.  Treatment of complications from polyacrylamide hydrogel breast augmentation.

Authors:  Wang Wei
Journal:  Exp Ther Med       Date:  2016-05-09       Impact factor: 2.447

  10 in total