Literature DB >> 19451023

Performance of OraQuick Advance Rapid HIV-1/2 Antibody Test for detection of antibodies in oral fluid and serum/plasma in HIV-1+ subjects carrying different HIV-1 subtypes and recombinant variants.

Africa Holguín1, Maite Gutiérrez, Nieves Portocarrero, Pablo Rivas, Margarita Baquero.   

Abstract

BACKGROUND: Rapid, simple, low-cost, sensitive, and specific tests are needed to detect antibodies to all HIV-1 subtypes, especially in developing countries.
OBJECTIVE: To evaluate the performance of a rapid diagnostic test for detection of HIV-1/2 antibodies in oral fluids and sera/plasma from subjects from geographic areas infected with different HIV-1 variants. STUDY
DESIGN: OraQuick Rapid HIV-1/2 Diagnostic Test was evaluated in sera and oral fluids from 100 subjects from Spain and South-America. It was also assessed in 56 plasma and 39 oral fluid specimens from 56 Africans carrying HIV-1 non-B subtypes or inter-subtype recombinants defined by phylogenetic analysis at pol and gp41 coding regions. All patients were previously diagnosed as HIV-1 positive by serological tests (Abbott AxSYM HIV-1/2; Western Blot HIV-1/HIV-2 and Pepti-LAV, BIO-RAD).
RESULTS: OraQuick provided positive results in all 156 serum/plasma specimens regardless of the infecting HIV-1 subtype, and in 136/139 (97.8%) oral fluids. The three oral specimens (2.2%) that yielded false-negative results by OraQuick were taken from one subtype B-infected Spaniard and from two subtype D-infected Africans. The last two were also negative by Pepti-LAV using plasma samples. Ten additional sera and 32 oral fluids from HIV-negative individuals yielded negative results by OraQuick. This rapid test showed good sensitivity for detecting anti-HIV-1 antibodies in oral fluids and in serum/plasma specimens from subjects carrying different HIV-1 subtypes and recombinant variants.
CONCLUSION: OraQuick demonstrated its utility for detecting infections due to HIV-1 subtypes and recombinants common in developing countries.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19451023     DOI: 10.1016/j.jcv.2009.04.002

Source DB:  PubMed          Journal:  J Clin Virol        ISSN: 1386-6532            Impact factor:   3.168


  6 in total

Review 1.  Toward integrated molecular diagnostic system (i MDx): principles and applications.

Authors:  Seung-Min Park; Andrew F Sabour; Jun Ho Son; Sang Hun Lee; Luke P Lee
Journal:  IEEE Trans Biomed Eng       Date:  2014-05       Impact factor: 4.538

2.  Community-based rapid oral human immunodeficiency virus testing for tuberculosis patients in Lima, Peru.

Authors:  Adrianne K Nelson; Adolfo Caldas; Jose Luis Sebastian; Maribel Muñoz; Cesear Bonilla; Jose Yamanija; Oswaldo Jave; Christina Magan; Judith Saldivar; Betty Espiritu; Gustavo Rosell; Jaime Bayona; Sonya Shin
Journal:  Am J Trop Med Hyg       Date:  2012-07-23       Impact factor: 2.345

3.  What's the Point? How Point-of-Care STI Tests Can Impact Infected Patients.

Authors:  Jill Huppert; Elizabeth Hesse; Charlotte A Gaydos
Journal:  Point Care       Date:  2010-03-01

4.  Analysis of False-Negative Human Immunodeficiency Virus Rapid Tests Performed on Oral Fluid in 3 International Clinical Research Studies.

Authors:  Marcel E Curlin; Roman Gvetadze; Wanna Leelawiwat; Michael Martin; Charles Rose; Richard W Niska; Tebogo M Segolodi; Kachit Choopanya; Jaray Tongtoyai; Timothy H Holtz; Taraz Samandari; Janet M McNicholl
Journal:  Clin Infect Dis       Date:  2017-06-15       Impact factor: 9.079

5.  Sensitivity of five rapid HIV tests on oral fluid or finger-stick whole blood: a real-time comparison in a healthcare setting.

Authors:  Juliette Pavie; Anne Rachline; Bénédicte Loze; Laurence Niedbalski; Constance Delaugerre; Eric Laforgerie; Jean-Christophe Plantier; Willy Rozenbaum; Sylvie Chevret; Jean-Michel Molina; François Simon
Journal:  PLoS One       Date:  2010-07-19       Impact factor: 3.240

6.  Finger-stick whole blood HIV-1/-2 home-use tests are more sensitive than oral fluid-based in-home HIV tests.

Authors:  Marie Jaspard; Gwenaël Le Moal; Mariam Saberan-Roncato; David Plainchamp; Aurélie Langlois; Pascale Camps; Aurélie Guigon; Laurent Hocqueloux; Thierry Prazuck
Journal:  PLoS One       Date:  2014-06-27       Impact factor: 3.240

  6 in total