Literature DB >> 19447688

Hollow fiber liquid phase microextraction followed by high performance liquid chromatography for determination of ultra-trace levels of Se(IV) after derivatization in urine, plasma and natural water samples.

Abolfazl Saleh1, Yadollah Yamini, Mohammad Faraji, Shahab Shariati, Mohammad Rezaee.   

Abstract

In the present work, a simple and high sensitive method based on hollow fiber liquid phase microextraction (HF-LPME) was developed followed by high performance liquid chromatography (HPLC) for determination of ultra-trace amounts of Se(IV) after derivatization in biological and natural water samples. Se(IV) was complexed with o-phenylenediamine to form piazselenol. The formed piazselenol was extracted into 20 microL of 1-octanol located in the lumen of a hollow fiber and the solution was injected into HPLC-UV for analysis. Using the Taguchi method, an orthogonal array design (OAD), OA(16) (4(5)) was employed to optimize the HF-LPME of piazselenol. The effect of five experimental factors (each factor at four levels) including the volume of the organic phase, extraction time, pH of the solution, stirring rate and ionic strength on the extraction efficiency of piazselenol was studied and optimized. The maximum extraction efficiency of piazselenol was obtained at 20 microL of 1-octanol as the extracting solvent, 30 min extraction time, pH 2, stirring rate of 500 rpm and 30% (w/v) NaCl. Under the optimum conditions, preconcentration factors up to 130 were achieved and the relative standard deviation (%RSD) of the method was <3.7% for different concentrations of Se(IV). The calibration curves were obtained in the ranges of 0.2-100 and 0.05-10 microgL(-1) for the 11 and 50 mL of the sample volumes with reasonable linearity, respectively (r(2)> 0.995). The limits of detection (LOD) were 0.1 and 0.02 microgL(-1) for the 11 and 50 mL sample volumes, respectively (S/N - 3). Finally, the applicability of the proposed method was evaluated by the extraction and determination of Se(IV) in the plasma, urine and water samples.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19447688     DOI: 10.1016/j.jchromb.2009.04.039

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  3 in total

1.  Chromatographic Determination of Total Selenium in Biofortified Allium sp. following Piazselenol Formation and Micro-Solid-Phase Extraction.

Authors:  Bogdan M Bosca; Augustin C Mot
Journal:  Molecules       Date:  2021-11-06       Impact factor: 4.411

2.  Development of Hollow-Fiber Liquid-Phase Microextraction Method for Determination of Urinary trans,trans-Muconic Acid as a Biomarker of Benzene Exposure.

Authors:  Farhad Ghamari; Abdulrahman Bahrami; Yadollah Yamini; Farshid Ghorbani Shahna; Abbas Moghimbeigi
Journal:  Anal Chem Insights       Date:  2016-09-11

Review 3.  Application of hollow fiber liquid phase microextraction and dispersive liquid-liquid microextraction techniques in analytical toxicology.

Authors:  Vahid Sharifi; Ali Abbasi; Anahita Nosrati
Journal:  J Food Drug Anal       Date:  2016-01-07       Impact factor: 6.157

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.