Literature DB >> 19447666

Development of a 4-axis load cell used for lumbar interbody load measurements.

Constantine K Demetropoulos1, Craig R Morgan, Dilip K Sengupta, Harry N Herkowitz.   

Abstract

Numerous studies have assessed lumbar interbody fusion, but little data from direct interbody load measurements exists. This manuscript describes an interbody fusion cage with integrated 4-axis load cell that can simulate implant heights of 13, 15, 17, 19 and 21 mm. The calibrated load cell was accurate to within 7.9% for point compressive loads over the central 8 mm x 8 mm region, but up to 26.8% for eccentric loads on the outer 16 mm x 16 mm rim of the device (although typically errors were less than half). Anterior-posterior shear and lateral shear loads did not affect compressive load measurement (<1.0% and <3.5%, respectively). Moments calculated from 4 load sensing corner pillars demonstrated errors below 2.3% in lateral bending and 2.1% in flexion-extension. Although this device does not have the accuracy of other much larger corpectomy implants, it incorporates four channels of load and simulates multiple implant heights, making for a favorable comparison in this restricted space. This device has immediate use in cadaveric testing, providing data previously not attainable, and serves as a novel technological step towards an implantable interbody device with multi-axis load sensing capability. As per the authors' knowledge, no such device has previously been described.

Mesh:

Year:  2009        PMID: 19447666     DOI: 10.1016/j.medengphy.2009.04.002

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  4 in total

1.  Design of a Sensor System for On-Line Monitoring of Contact Pressure in Chalcographic Printing.

Authors:  José Antonio Jiménez; Francisco Javier Meca; Enrique Santiso; Pedro Martín
Journal:  Sensors (Basel)       Date:  2017-09-05       Impact factor: 3.576

2.  Adjustable Rigid Interspinous Process Fixation: A Biomechanical Study of Segmental Lordosis and Interbody Loading in the Lumbar Spine.

Authors:  Anup Gandhi; Chris Ferry; Jason A Inzana; Steve W Chang; Ryan DenHaese
Journal:  Cureus       Date:  2019-03-25

3.  Logarithmic Strain Model for Nonlinear Load Cell.

Authors:  Young-Dae Hong; Bumjoo Lee
Journal:  Sensors (Basel)       Date:  2019-08-09       Impact factor: 3.576

4.  Smart implants in orthopedic surgery, improving patient outcomes: a review.

Authors:  Eric H Ledet; Benjamin Liddle; Katerina Kradinova; Sara Harper
Journal:  Innov Entrep Health       Date:  2018-08-29
  4 in total