Literature DB >> 19445060

Breath pentane: an indicator for early and continuous monitoring of lipid peroxidation in hepatic ischaemia-reperfusion injury.

Peng Li1, Guowang Xu, Changsong Wang, Yulei Gong, Ying He.   

Abstract

BACKGROUND AND
OBJECTIVE: Lipid peroxidation plays an important role during liver ischaemia-reperfusion injury. Pentane in breath is often used as an index of lipid peroxidation. We observed the changes in levels of breath pentane during the lipid peroxidation process caused by liver ischaemia-reperfusion injury.
METHODS: Ten male swine were anaesthetized with chloral hydrate 0.3-0.5 g kg(-1) min(-1). Total hepatic ischaemia was induced by occluding the portal inflow vessels. Ischaemia lasted 30 min followed by reperfusion for 180 min. Breath samples were sampled from the anaesthesia circuit and blood samples were collected from the inferior vena cava. Pentane concentrations in breath and blood were quantified by means of solid phase microextraction and gas chromatography-mass spectrography technique.
RESULTS: Exhaled pentane concentrations (means +/- SE) increased markedly after reperfusion for 1 min (244.13 +/- 33.3 pmol l(-1)) and decreased gradually to initial levels after reperfusion for 60 min. Blood pentane concentrations (means +/- SE) increased significantly after reperfusion for 1 min (333.46 +/- 63.05 pmol l(-1)) and then decreased to basal level. Breath pentane concentrations showed a correlation with blood (r = 0.709, P < 0.05).
CONCLUSION: Breath pentane analysis could provide early, rapid, noninvasive and continuous assessment of lipid peroxidation during hepatic ischaemia-reperfusion injury.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19445060     DOI: 10.1097/eja.0b013e328326f7b7

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  3 in total

1.  Time-course and intensity-based classifications of oxidative stresses and their potential application in biomedical, comparative and environmental research.

Authors:  Volodymyr I Lushchak
Journal:  Redox Rep       Date:  2016-02-05       Impact factor: 4.412

2.  Breath analysis using laser spectroscopic techniques: breath biomarkers, spectral fingerprints, and detection limits.

Authors:  Chuji Wang; Peeyush Sahay
Journal:  Sensors (Basel)       Date:  2009-10-19       Impact factor: 3.576

3.  Breath pentane as a potential biomarker for survival in hepatic ischemia and reperfusion injury--a pilot study.

Authors:  Changsong Wang; Jinghui Shi; Bo Sun; Desheng Liu; Peng Li; Yulei Gong; Ying He; Shujuan Liu; Guowang Xu; Jianyi Li; Ailin Luo; Enyou Li
Journal:  PLoS One       Date:  2012-09-11       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.