Literature DB >> 19444346

Load sharing mechanism across graft-bone interface in static cervical locking plate fixation.

In Ho Han1, Sung Uk Kuh, Dong Kyu Chin, Byung Ho Jin, Yong Eun Cho, Keun Su Kim.   

Abstract

OBJECTIVE: This study is a retrospective clinical study over more than 4 years of follow up to understand the mechanism of load sharing across the graft-bone interface in the static locking plate (SLP) fixation compared with non-locking plate (NLP).
METHODS: Orion locking plates and Top non-locking plates were used for SLP fixation in 29 patients and NLP fixation in 24 patients, respectively. Successful interbody fusion was estimated by dynamic X-ray films. The checking parameters were as follows : screw angle (SA) between upper and lower screw, anterior and posterior height of fusion segment between upper and lower endplate (AH & PH), and upper and lower distance from vertebral endplate to the end of plate (UD & LD). Each follow-up value of AH and PH were compared to initial values. Contributions of upper and lower collapse to whole segment collapse were estimated.
RESULTS: Successful intervertebral bone fusion rate was 100% in the SLP group and 92% in the NLP group. The follow-up mean value of SA in SLP group was not significantly changed compared with initial value, but follow-up mean value of SA in NLP group decreased more than those in SLP group (p=0.0067). Statistical analysis did not show a significant difference in the change in AH and PH between SLP and NLP groups (p>0.05). Follow-up AH of NLP group showed more collapse than PH of same group (p=0.04). The upper portion of the vertebral body collapsed more than the lower portion in the SLP fixation (p=0.00058).
CONCLUSION: The fused segments with SLP had successful bone fusion without change in initial screw angle, which was not observed in NLP fixation. It suggests that there was enough load sharing across bone-graft interface in SLP fixation.

Entities:  

Keywords:  Cervical vertebrae; Spinal fusion; Surgical Fixation Devices

Year:  2009        PMID: 19444346      PMCID: PMC2682116          DOI: 10.3340/jkns.2009.45.4.213

Source DB:  PubMed          Journal:  J Korean Neurosurg Soc        ISSN: 1225-8245


  31 in total

1.  The effect of locking fixation screws on the stability of anterior cervical plating.

Authors:  J M Spivak; D Chen; F J Kummer
Journal:  Spine (Phila Pa 1976)       Date:  1999-02-15       Impact factor: 3.468

2.  Anterior cervical fixation: analysis of load-sharing and stability with use of static and dynamic plates.

Authors:  Darrel S Brodke; Paul Klimo; Kent N Bachus; John T Braun; Andrew T Dailey
Journal:  J Bone Joint Surg Am       Date:  2006-07       Impact factor: 5.284

3.  Anterior cervical discectomy and fusion: analysis of surgical outcome with and without plating.

Authors:  Ralph J Mobbs; Prakash Rao; Nadana K Chandran
Journal:  J Clin Neurosci       Date:  2007-07       Impact factor: 1.961

4.  Reoperation in patients after anterior cervical plate stabilization in degenerative disease.

Authors:  F H Geisler; W Caspar; T Pitzen; T A Johnson
Journal:  Spine (Phila Pa 1976)       Date:  1998-04-15       Impact factor: 3.468

5.  Anterior cervical plate stabilization in one- and two-level degenerative disease: overtreatment or benefit?

Authors:  W Caspar; F H Geisler; T Pitzen; T A Johnson
Journal:  J Spinal Disord       Date:  1998-02

6.  Biomechanical evaluation of anterior cervical spine stabilization.

Authors:  M R Grubb; B L Currier; J S Shih; V Bonin; J J Grabowski; E Y Chao
Journal:  Spine (Phila Pa 1976)       Date:  1998-04-15       Impact factor: 3.468

7.  The significance of hardware failure in anterior cervical plate fixation. Patients with 2- to 7-year follow-up.

Authors:  G L Lowery; R F McDonough
Journal:  Spine (Phila Pa 1976)       Date:  1998-01-15       Impact factor: 3.468

Review 8.  Outcome analysis of noninstrumented anterior cervical discectomy and interbody fusion in 348 patients.

Authors:  J C Cauthen; R E Kinard; J B Vogler; D E Jackson; O B DePaz; O L Hunter; L B Wasserburger; V M Williams
Journal:  Spine (Phila Pa 1976)       Date:  1998-01-15       Impact factor: 3.468

9.  Anterior cervical fusion with the Orion locking plate system.

Authors:  V Heidecke; N G Rainov; W Burkert
Journal:  Spine (Phila Pa 1976)       Date:  1998-08-15       Impact factor: 3.468

10.  Stress-shielding compared with load-sharing anterior cervical plate fixation: a clinical and radiographic prospective analysis of 50 patients.

Authors:  Paul S Saphier; Marc S Arginteanu; Frank M Moore; Alfred A Steinberger; Martin B Camins
Journal:  J Neurosurg Spine       Date:  2007-05
View more
  1 in total

1.  A unique modular implant system enhances load sharing in anterior cervical interbody fusion: a finite element study.

Authors:  Vivek Palepu; Ali Kiapour; Vijay K Goel; James M Moran
Journal:  Biomed Eng Online       Date:  2014-03-11       Impact factor: 2.819

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.