Literature DB >> 19439019

Rapid bead-based immunoassay for measurement of mannose-binding lectin.

J T Bay1, P Garred.   

Abstract

Mannose-binding lectin (MBL) is a serum protein, which functions as an opsonin and initiator of the lectin pathway of complement. The serum concentration of MBL shows great interindividual variation because of common polymorphisms in the MBL2 gene. Although several quantitative MBL immunoassays have been developed more automated platforms for MBL analysis is urgently needed. To pursue this, we set out to develop a flexible bead-based MBL immunoassay. Serum was obtained from 98 healthy individuals and 50 patients investigated for possible immunodeficiencies. We used the Luminex xMAP bead array technology employing a mouse monoclonal anti-MBL antibody both for coating and detection. The assay was fast and reliable for measurements of MBL concentrations both in the lower and upper range. The lower detection limit was found to be 6.5 microg/l. The intra-assay coefficient and the interassay coefficient were found be 7.88% and 5.70%, respectively. A close correlation between the new assay and a reference MBL measurement ELISA was found (rho 0.9381, P < 0.0001). The bead-based assay was less sensitive to interfering anti-murine antibodies in the blood samples than when the antibodies employed were used in the reference polystyrene-based ELISA. The new assay could be performed in 3 h with less than 25 microl serum required of each sample. These results show that MBL can be measured readily using a bead-based platform, which may form an efficient basis for a multiplex approach to measure different antigens in the same sample.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19439019     DOI: 10.1111/j.1365-3083.2009.02248.x

Source DB:  PubMed          Journal:  Scand J Immunol        ISSN: 0300-9475            Impact factor:   3.487


  3 in total

1.  Quantification of Complement Proteins with Special Reference to C1q: Multiplex Versus ELISA Versus Rocket Immunoelectrophoresis Versus Nephelometry.

Authors:  Kerstin Sandholm; Barbro Persson; Sliva Abdalla; Camilla Mohlin; Bo Nilsson; Kristina N Ekdahl
Journal:  Methods Mol Biol       Date:  2021

2.  Standardization and validation of a cytometric bead assay to assess antibodies to multiple Plasmodium falciparum recombinant antigens.

Authors:  Bartholomew N Ondigo; Gregory S Park; Severin O Gose; Benjamin M Ho; Lyticia A Ochola; George O Ayodo; Ayub V Ofulla; Chandy C John
Journal:  Malar J       Date:  2012-12-21       Impact factor: 2.979

3.  High levels of mannose-binding lectin are associated with lower pulse wave velocity in uraemic patients.

Authors:  Mads Hornum; Jakob T Bay; Peter Clausen; Jesper Melchior Hansen; Elisabeth R Mathiesen; Bo Feldt-Rasmussen; Peter Garred
Journal:  BMC Nephrol       Date:  2014-10-04       Impact factor: 2.388

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.