Literature DB >> 19438959

Precision of fit to implants: a comparison of Cresco™ and Procera® implant bridge frameworks.

Lars Hjalmarsson1, Anders Örtorp, Jan-Ivan Smedberg, Torsten Jemt.   

Abstract

BACKGROUND: The Cresco™ (Astra Tech AB, Mölndal, Sweden) method aims to reduce the inevitable distortions when cast metal frameworks for implant-supported prostheses are fabricated. However, limited data are available for the precision of fit for this method.
PURPOSE: To measure and compare the precision of fit of Cresco- and computer numeric controlled (CNC)-milled metal frameworks for implant-supported fixed complete prostheses.
MATERIALS AND METHODS: Two groups of frameworks were fabricated according to the Cresco method, either in titanium (Cresco-Ti, n = 10) or in a cobalt-chrome alloy (Cresco-CoCr, n = 10). A third group comprised CNC-milled titanium frameworks (Procera® Implant Bridge [PIB], Nobel Biocare AB, Göteborg, Sweden), made from individual model/pattern measurements (PIB, n = 5). Measurements of fit were performed by means of a coordinate measuring machine linked to a computer. The collected data on distortions were analyzed.
RESULTS: Overall, a maximal three-dimensional range of center point distortion of 279 µm was observed for measured frameworks. The framework width (x-axis) decreased for Cresco-CoCr, but increased in Cresco-Ti and PIB; Cresco-CoCr compared to Cresco-Ti (p = .0002) and Cresco-CoCr compared to PIB (p < .0001). In vertical dimension (z-axis), less distortions were present in PIB compared to Cresco-CoCr (p = .0007) and in PIB compared to Cresco-Ti (p < .0001).
CONCLUSIONS: None of the frameworks presented a perfect, completely "passive fit" to the master. Although the direction of distortions varied, the horizontal distortions were of similar magnitudes. However, the PIB frameworks had statistical significant less vertical distortions as compared to the Cresco groups.
© 2009, Copyright the Authors. Journal Compilation © 2010, Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 19438959     DOI: 10.1111/j.1708-8208.2009.00171.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  5 in total

1.  The effect of framework fabrication technique on the fit accuracy of full arch screw retained implant supported prostheses.

Authors:  Fellwa AlRasheed; Khalid AlWazzan
Journal:  Saudi Dent J       Date:  2022-04-02

2.  Effects of Different Surface Treatments on Bond Strength of Resin Cement to Machined Pure Titanium.

Authors:  Yang Cao; Yan-Yang Guo; Lei Chen; Jing Han; Hui Tong; Bao Zhang; Yu Zhang
Journal:  J Adhes Dent       Date:  2019       Impact factor: 2.359

3.  Precision of fit of titanium and cast implant frameworks using a new matching formula.

Authors:  Marianella Sierraalta; Jose L Vivas; Michael E Razzoog; Rui-Feng Wang
Journal:  Int J Dent       Date:  2012-04-08

4.  Dimensional Changes of 3-Unit Implant-Supported Zirconia Frameworks of Two CAD/CAM Systems from Scanning to Sintering.

Authors:  Marzieh Alikhasi; Narges Ameri; Hakimeh Siadat; Ahmad Reza Shamshiri; Mohammadreza Nejati
Journal:  Front Dent       Date:  2019-06-29

5.  Fit of cobalt-chromium implant frameworks before and after ceramic veneering in comparison with CNC-milled titanium frameworks.

Authors:  Per Svanborg; Victoria Stenport; Alf Eliasson
Journal:  Clin Exp Dent Res       Date:  2015-10-26
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.