Literature DB >> 19438775

Determination of pump flow rate during cardiopulmonary bypass in obese patients avoiding hemodilution.

Luisa Santambrogio1, Cristian Leva, Giorgio Musazzi, Piergiorgio Bruno, Andrea Vailati, Franco Zecchillo, Germano Di Credico.   

Abstract

BACKGROUND AND AIM: During cardiopulmonary bypass the pump flow is usually set on 2.4 L/min/m(2) of body surface area (BSA) to guarantee adequate tissue perfusion without differences for patient constitutional type. The present study attempts to evaluate the adequacy of pump flow rate in obese patients, considering the ideal weight instead of the real one, avoiding the overflow side effects and hemodilution.
METHODS: Obese patients with body mass index (BMI) > 30 presented for cardiac surgery were randomized in two groups: in one the cardiopulmonary bypass was led traditionally, in the other, pump flow rate was calculated on ideal BMI of 25.
RESULTS: Demographics, preoperative tests, and monitoring data were registered. Mortality at hospital discharge and 30 days after were analyzed. The pump flow rate between the groups was different (4.46 vs. 4.87; p = 0.004); there were no differences in organ perfusion (SvO(2); diuresis) and mortality, but the study group presented fewer complications and blood transfusions.
CONCLUSIONS: The BSA is widely used as the biometric unit to normalize physiologic parameters included pump flow rate, but it is disputable if this practice is correct also in obese patients. The study group, in which pump flow rate was set on ideal BSA, presented no difference in diuresis and mixed venous saturation but fewer complications and fewer perioperative blood transfusions.

Entities:  

Mesh:

Year:  2009        PMID: 19438775     DOI: 10.1111/j.1540-8191.2008.00792.x

Source DB:  PubMed          Journal:  J Card Surg        ISSN: 0886-0440            Impact factor:   1.620


  5 in total

1.  Going beyond manufacturers' limitations is not in the best interest of our patients.

Authors:  Gerard J Myers
Journal:  J Extra Corpor Technol       Date:  2014-03

Review 2.  Acute Kidney Injury Subsequent to Cardiac Surgery.

Authors:  Robert S Kramer; Crystal R Herron; Robert C Groom; Jeremiah R Brown
Journal:  J Extra Corpor Technol       Date:  2015-03

3.  Lean Flow: Optimizing Cardiopulmonary Bypass Equipment and Flow for Obese Patients-A Technique Article.

Authors:  Joshua M Blessing; Jeffrey B Riley
Journal:  J Extra Corpor Technol       Date:  2017-03

4.  Emergent cardiopulmonary bypass for a 180 kilogram patient: support with a single oxygenator.

Authors:  Kyler T Hunter; Angela R Lopez; Kwok L Yun
Journal:  J Extra Corpor Technol       Date:  2013-09

5.  Ghrelin Pre-treatment Attenuates Local Oxidative Stress and End Organ Damage During Cardiopulmonary Bypass in Anesthetized Rats.

Authors:  Vijayakumar Sukumaran; Hirotsugu Tsuchimochi; Yutaka Fujii; Hiroshi Hosoda; Kenji Kangawa; Tsuyoshi Akiyama; Mikiyasu Shirai; Eisuke Tatsumi; James T Pearson
Journal:  Front Physiol       Date:  2018-03-09       Impact factor: 4.566

  5 in total