Literature DB >> 19430260

Removal of a bent intramedullary nail with a posttraumatic sagittal plane deformity.

Rahul Banerjee1, Matthew Posner.   

Abstract

High-energy injuries may result in a femur fracture with resultant bending of a previously placed intramedullary femoral nail. A bend of the nail in the sagittal plane presents unique challenges for nail extraction and subsequent exchange nailing. The described surgical technique illustrates a simple method to straighten the sagittal plane bend in situ and performs exchange nailing although maintaining symmetric femoral length and rotation.

Entities:  

Mesh:

Year:  2009        PMID: 19430260     DOI: 10.1097/TA.0b013e31818a6d4b

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  4 in total

1.  Jumbo Cutter for Removal of A Bent Femoral Interlocking Nail: A Cost Effective Method.

Authors:  Manjeet Singh Dhanda; Harnam Singh Madan; Sansar C Sharma; Nadeem Ali; Abedullah Bhat
Journal:  J Clin Diagn Res       Date:  2015-06-01

2.  Surgical management of angulated femoral intramedullary nails associated with closed fractures: A systematic review of the literature.

Authors:  Mark L Dunleavy; Alex Burton; J Spence Reid; Carol E Copeland
Journal:  J Orthop       Date:  2020-06-06

3.  Removal of bent intramedullary nail: Two case reports.

Authors:  You-Sung Suh; Won-Seok Lee; Joonghyun Ahn; Hyung-Suk Choi; Min Jung Baek; Sung-Woo Choi
Journal:  Medicine (Baltimore)       Date:  2020-05       Impact factor: 1.889

4.  Bent femoral intramedullary nail: a case report and review of the literature.

Authors:  Gianluca Canton; Bramir Haxhaj; Roberto Fattori; Luigi Murena
Journal:  Acta Biomed       Date:  2019-01-10
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.