Literature DB >> 19425669

Results of the National Institute for Occupational Safety and Health-U.S. Environmental Protection Agency interlaboratory comparison of American National Standards Institute S12.6-1997 Methods A and B.

William J Murphy1, David C Byrne, Dan Gauger, William A Ahroon, Elliott Berger, Samir N Y Gerges, Richard McKinley, Brad Witt, Edward F Krieg.   

Abstract

The National Institute for Occupational Safety and Health and the Environmental Protection Agency sponsored the completion of an interlaboratory study to compare two fitting protocols specified by ANSI S12.6-1997 (R2002) [(2002). American National Standard Methods for the Measuring Real-Ear Attenuation of Hearing Protectors, American National Standards Institute, New York]. Six hearing protection devices (two earmuffs, foam, premolded, custom-molded earplugs, and canal-caps) were tested in six laboratories using the experimenter-supervised, Method A, and (naive) subject-fit, Method B, protocols with 24 subjects per laboratory. Within-subject, between-subject, and between-laboratory standard deviations were determined for individual frequencies and A-weighted attenuations. The differences for the within-subject standard deviations were not statistically significant between Methods A and B. Using between-subject standard deviations from Method A, 3-12 subjects would be required to identify 6-dB differences between attenuation distributions. Whereas using between-subject standard deviations from Method B, 5-19 subjects would be required to identify 6-dB differences in attenuation distributions of a product tested within the same laboratory. However, the between-laboratory standard deviations for Method B were -0.1 to 3.0 dB less than the Method A results. These differences resulted in considerably more subjects being required to identify statistically significant differences between laboratories for Method A (12-132 subjects) than for Method B (9-28 subjects).

Mesh:

Year:  2009        PMID: 19425669     DOI: 10.1121/1.3095803

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  3 in total

1.  Inter-laboratory comparison of three earplug fit-test systems.

Authors:  David C Byrne; William J Murphy; Edward F Krieg; Robert M Ghent; Kevin L Michael; Earl W Stefanson; William A Ahroon
Journal:  J Occup Environ Hyg       Date:  2017-04       Impact factor: 2.155

2.  Measurement of impulse peak insertion loss from two acoustic test fixtures and four hearing protector conditions with an acoustic shock tube.

Authors:  William J Murphy; Cameron J Fackler; Elliott H Berger; Peter B Shaw; Mike Stergar
Journal:  Noise Health       Date:  2015 Sep-Oct       Impact factor: 0.867

3.  The effect of earplug training on noise protection.

Authors:  Jung Won Kim; Seonhee Yang; Insung Chung; Mi-Young Lee
Journal:  Ann Occup Environ Med       Date:  2019-11-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.