Literature DB >> 19424083

Engineering aspects of the quantified amplitude-integrated electroencephalogram in neonatal cerebral monitoring.

Mark Quigg1, Derek Leiner.   

Abstract

Amplitude-integrated electroencephalography (aEEG) is used for determination of severity of hypoxic-ischemic encephalopathy and eligibility for hypothermia therapy in infants. We evaluate susceptibility of the aEEG to machine differences, impedance mismatch, electrode placement, and interelectrode distance in preparation for further clinical studies. Frequency-response curves were obtained from manufacturers of aEEG systems. The mean of the quantified aEEG and the median lower border of amplitude were derived from digital EEG recordings. Impedance effects were evaluated by inserting resistors ranging from 1 kOmega to1 MOmega into inputs G1/G2 while recording from a looped-signal generator. Interelectrode distance effects were evaluated from simultaneous recordings from electrodes placed at 5% to 30% of the preauricular notch distance from a healthy human subject. Electrode location effects were evaluated by comparing Q-aEEG from C3-C4 versus P3-P4 from 10 term infants. Frequency-response curves differed up to 20 dB for particular frequencies. Impedance mismatch distorted EEG and aEEG, but did not significantly change Q-aEEG. Increasing interelectrode distances significantly increased Q-aEEG. Central Q-aEEG values were significantly higher than parietal. Comparisons of aEEG must carefully account for differences in machines, interelectrode distances, and electrode locations. Q-aEEG may offer a rigorous method of evaluating hypoxic-ischemic encephalopathy.

Entities:  

Mesh:

Year:  2009        PMID: 19424083     DOI: 10.1097/WNP.0b013e3181a18711

Source DB:  PubMed          Journal:  J Clin Neurophysiol        ISSN: 0736-0258            Impact factor:   2.177


  5 in total

Review 1.  Neonatal seizures and status epilepticus.

Authors:  Nicholas S Abend; Courtney J Wusthoff
Journal:  J Clin Neurophysiol       Date:  2012-10       Impact factor: 2.177

2.  Predictive value of an early amplitude integrated electroencephalogram and neurologic examination.

Authors:  Seetha Shankaran; Athina Pappas; Scott A McDonald; Abbot R Laptook; Rebecca Bara; Richard A Ehrenkranz; Jon E Tyson; Ronald Goldberg; Edward F Donovan; Avroy A Fanaroff; Abhik Das; W Kenneth Poole; Michele Walsh; Rosemary D Higgins; Cherie Welsh; Walid Salhab; Waldemar A Carlo; Brenda Poindexter; Barbara J Stoll; Ronnie Guillet; Neil N Finer; David K Stevenson; Charles R Bauer
Journal:  Pediatrics       Date:  2011-06-13       Impact factor: 7.124

3.  Instantaneous measure of EEG channel importance for improved patient-adaptive neonatal seizure detection.

Authors:  Andriy Temko; Gordon Lightbody; Eoin M Thomas; Geraldine B Boylan; William Marnane
Journal:  IEEE Trans Biomed Eng       Date:  2011-12-07       Impact factor: 4.538

4.  Application of an Amplitude-integrated EEG Monitor (Cerebral Function Monitor) to Neonates.

Authors:  Nora Bruns; Susanne Blumenthal; Irmgard Meyer; Susanne Klose-Verschuur; Ursula Felderhoff-Müser; Hanna Müller
Journal:  J Vis Exp       Date:  2017-09-06       Impact factor: 1.355

Review 5.  Electroencephalographic studies in growth-restricted and small-for-gestational-age neonates.

Authors:  Nathan J Stevenson; Melissa M Lai; Hava E Starkman; Paul B Colditz; Julie A Wixey
Journal:  Pediatr Res       Date:  2022-02-23       Impact factor: 3.756

  5 in total