Literature DB >> 19423360

A literature review of the methodology of EMG recordings of the diaphragm.

G J Hutten1, H F van Thuijl, A C M van Bellegem, L A van Eykern, W M C van Aalderen.   

Abstract

INTRODUCTION: EMG measurements of the diaphragm (rEMG) provide insight in to ventilatory muscle activity. Applicability of these measurements has improved, but literature of the different rEMG measurement techniques is inconsistent. This makes it difficult to compare studies of rEMG technique. This study summarizes the current available literature on rEMG and focuses on the validation of the techniques. Furthermore, we propose to use validation criteria to improve the quality, for further research.
METHODS: Pubmed, Ovid Medline and EMBASE were searched for studies describing rEMG experiments with transcutaneous (tc-rEMG) and/or transesophageal (te-rEMG) methods.Validation criteria included feasibility, repeatability, signal disturbance and ECG gating.
RESULTS: 650 studies were eligible for reviewing; 211 were excluded, and 39 articles described the measurement technique and were analyzed according to the criteria. 194 studies referred to another paper with a description of the technique and 206 failed to describe the technique nor had references to it.
CONCLUSIONS: Many studies showed neither a description of the technique used, nor a validation of this technique. Others referred to studies that described the measurement technique. We propose that future studies on rEMG measurements at least meet the above mentioned criteria, in order to be able to compare study results. 2009 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 19423360     DOI: 10.1016/j.jelekin.2009.02.008

Source DB:  PubMed          Journal:  J Electromyogr Kinesiol        ISSN: 1050-6411            Impact factor:   2.368


  5 in total

1.  Guiding intramuscular diaphragm injections using real-time ultrasound and electromyography.

Authors:  Aarti Sarwal; Michael S Cartwright; Erin Mitchell; Koudy Williams; Francis O Walker; Martin K Childers
Journal:  Muscle Nerve       Date:  2015-02       Impact factor: 3.217

2.  Seronegative neuromyelitis optica presenting with life-threatening respiratory failure.

Authors:  Raffaele Nardone; Giulio Zuccoli; Francesco Brigo; Eugen Trinka; Ryan T Fitzgerald
Journal:  J Spinal Cord Med       Date:  2015-12-18       Impact factor: 1.985

3.  Diaphragmatic electromyography in preterm infants: The influence of electrode positioning.

Authors:  Ruud W van Leuteren; Robin E Bekhuis; Cornelia G de Waal; Frans H de Jongh; Anton H van Kaam; Gerard J Hutten
Journal:  Pediatr Pulmonol       Date:  2019-11-25

4.  Discussion of the Influence of Multiscale PCA Denoising Methods with Three Different Features.

Authors:  Chizhou Zhang; Tao Sun
Journal:  Sensors (Basel)       Date:  2022-02-18       Impact factor: 3.576

5.  Respiratory bi-directional pressure and flow data collection device with thoracic and abdominal circumferential monitoring.

Authors:  Ella F S Guy; J Geoffrey Chase; Lui R Holder-Pearson
Journal:  HardwareX       Date:  2022-08-27
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.