Literature DB >> 19423098

Reducing blood loss at myomectomy with use of a gelatin-thrombin matrix hemostatic sealant.

Francisco Raga1, Magda Sanz-Cortes, Francisco Bonilla, Eva María Casañ, Fernando Bonilla-Musoles.   

Abstract

OBJECTIVE: To evaluate the hemostatic efficacy and handling of gelatin-thrombin matrix in abdominal myomectomy.
DESIGN: Prospective and randomized trial.
SETTING: University teaching hospital. PATIENT(S): Women (n = 50) with uterine fibroids with a uterine size equivalent to > or =16 weeks gestation. INTERVENTION(S): Gelatin-thrombin matrix (FloSeal Matrix; Baxter Healthcare Corp., Fremont, CA) was delivered to the site of the uterine bleeding during myomectomy. MAIN OUTCOME MEASURE(S): Patient age, parity, number of myomas, operative time, blood loss, transfusion, intraoperative and postoperative complications, and length of hospitalization were evaluated. RESULT(S): The average blood loss during surgery was 80 +/- 25.5 mL for the FloSeal group and 625 +/- 120.5 mL for the control group. Intraoperative blood transfusion was necessary in five patients from the control group. Postoperative blood loss was 25 +/- 5 mL for the FloSeal group and 250 +/- 75 mL for the control group. Length of the postoperative hospital stay was 2.5 +/- 1.2 days for FloSeal group and 4.5 +/- 1.3 for the control group. No major immediate or delayed complications were observed in either group. CONCLUSION(S): Reductions in hemorrhage in FloSeal-treated women undergoing a myomectomy are encouraging, and provide evidence for the ability of gelatin-thrombin matrix to reduce blood loss when applied immediately and directly to bleeding uterine tissue.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19423098     DOI: 10.1016/j.fertnstert.2008.04.038

Source DB:  PubMed          Journal:  Fertil Steril        ISSN: 0015-0282            Impact factor:   7.329


  14 in total

1.  Bleeding control in pedicle subtraction osteotomy.

Authors:  Claudio Lamartina; Giovanni Casero
Journal:  Eur Spine J       Date:  2011-12       Impact factor: 3.134

2.  The use of novel hemostatic sealant (Tisseel) in laparoscopic myomectomy: a case-control study.

Authors:  Roberto Angioli; Francesco Plotti; Roberto Ricciardi; Corrado Terranova; Marzio Angelo Zullo; Patrizio Damiani; Roberto Montera; Federica Guzzo; Giuseppe Scaletta; Ludovico Muzii
Journal:  Surg Endosc       Date:  2012-02-01       Impact factor: 4.584

Review 3.  The evolution of cancer surgery and future perspectives.

Authors:  Lynda Wyld; Riccardo A Audisio; Graeme J Poston
Journal:  Nat Rev Clin Oncol       Date:  2014-11-11       Impact factor: 66.675

4.  Improvement of Perioperative Outcomes in Major Gynecological and Gynecologic-Oncological Surgery with Hemostatic Gelatin-Thrombin Matrix.

Authors:  Rafał Watrowski; Christoph Jäger; Johannes Forster
Journal:  In Vivo       Date:  2017 Mar-Apr       Impact factor: 2.155

5.  Haemostatics in surgery and our experience in the enucleoresection of renal cell carcinoma.

Authors:  Gianna Pace; Pietro Saldutto; Carlo Vicentini; Lucio Miano
Journal:  World J Surg Oncol       Date:  2010-05-12       Impact factor: 2.754

Review 6.  Interventions to reduce haemorrhage during myomectomy for fibroids.

Authors:  Eugene J Kongnyuy; Charles Shey Wiysonge
Journal:  Cochrane Database Syst Rev       Date:  2014-08-15

7.  Effects of Human Mesenchymal Stem Cells Isolated from Wharton's Jelly of the Umbilical Cord and Conditioned Media on Skeletal Muscle Regeneration Using a Myectomy Model.

Authors:  T Pereira; P A S Armada-da Silva; I Amorim; A Rêma; A R Caseiro; A Gärtner; M Rodrigues; M A Lopes; P J Bártolo; J D Santos; A L Luís; A C Maurício
Journal:  Stem Cells Int       Date:  2014-10-14       Impact factor: 5.443

Review 8.  Use of Floseal®, a human gelatine-thrombin matrix sealant, in surgery: a systematic review.

Authors:  María Echave; Itziar Oyagüez; Miguel Angel Casado
Journal:  BMC Surg       Date:  2014-12-20       Impact factor: 2.102

9.  Comparison of two gelatin and thrombin combination hemostats in a porcine liver abrasion model.

Authors:  Kevin M Lewis; Holly D Atlee; Angela J Mannone; Joseph Dwyer; Lawrence Lin; Andreas Goppelt; Heinz Redl
Journal:  J Invest Surg       Date:  2013-03-20       Impact factor: 2.533

Review 10.  Use of a gelatin-thrombin hemostatic matrix in obstetrics and gynecological surgery.

Authors:  Selim Mısırlıoğlu; Engin Türkgeldi; Hande Yağmur; Bülent Urman; Barış Ata
Journal:  Turk J Obstet Gynecol       Date:  2018-09-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.