Literature DB >> 19423050

Fixation of the proximal interphalangeal arthrodesis with the use of an intraosseous loop of stainless-steel wire suture.

William Harris1, Gregory A Mote, D Scot Malay.   

Abstract

A wide range of options is available to surgeons for fixation of the proximal interphalangeal joint when arthrodesis is undertaken for repair of the hammertoe deformity. In this technical report, we describe the use of an intraosseous loop of stainless-steel wire for permanent stabilization of the interface between the proximal and middle phalanges during fusion of the interphalangeal joint.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19423050     DOI: 10.1053/j.jfas.2009.01.012

Source DB:  PubMed          Journal:  J Foot Ankle Surg        ISSN: 1067-2516            Impact factor:   1.286


  2 in total

1.  [Correction arthrodesis of the proximal interphalangeal joint with wire cerclage for rigid small toe deformities : a prospective study].

Authors:  N Gutteck; S Lebek; F Radetzki; D Wohlrab; K-S Delank
Journal:  Orthopade       Date:  2012-12       Impact factor: 1.087

Review 2.  [Research progress of interphalangeal arthrodesis].

Authors:  Fajiao Xiao; Yunfeng Yang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2020-09-15
  2 in total