Literature DB >> 19422731

Denoising forced-choice detection data.

Miguel A García-Pérez1.   

Abstract

Observers in a two-alternative forced-choice (2AFC) detection task face the need to produce a response at random (a guess) on trials in which neither presentation appeared to display a stimulus. Observers could alternatively be instructed to use a 'guess' key on those trials, a key that would produce a random guess and would also record the resultant correct or wrong response as emanating from a computer-generated guess. A simulation study shows that 'denoising' 2AFC data with information regarding which responses are a result of guesses yields estimates of detection threshold and spread of the psychometric function that are far more precise than those obtained in the absence of this information, and parallel the precision of estimates obtained with yes-no tasks running for the same number of trials. Simulations also show that partial compliance with the instructions to use the 'guess' key reduces the quality of the estimates, which nevertheless continue to be more precise than those obtained from conventional 2AFC data if the observers are still moderately compliant. An empirical study testing the validity of simulation results showed that denoised 2AFC estimates of spread were clearly superior to conventional 2AFC estimates and similar to yes-no estimates, but variations in threshold across observers and across sessions hid the benefits of denoising for threshold estimation. The empirical study also proved the feasibility of using a 'guess' key in addition to the conventional response keys defined in 2AFC tasks.

Mesh:

Year:  2009        PMID: 19422731     DOI: 10.1348/000711009X424057

Source DB:  PubMed          Journal:  Br J Math Stat Psychol        ISSN: 0007-1102            Impact factor:   3.380


  10 in total

1.  Factors affecting enhanced video quality preferences.

Authors:  Prem Nandhini Satgunam; Russell L Woods; P Matthew Bronstad; Eli Peli
Journal:  IEEE Trans Image Process       Date:  2013-12       Impact factor: 10.856

Review 2.  On the discrepant results in synchrony judgment and temporal-order judgment tasks: a quantitative model.

Authors:  Miguel A García-Pérez; Rocío Alcalá-Quintana
Journal:  Psychon Bull Rev       Date:  2012-10

3.  Motion adaptation does not depend on attention to the adaptor.

Authors:  Michael J Morgan
Journal:  Vision Res       Date:  2012-01-05       Impact factor: 1.886

4.  Psychometric functions for detection and discrimination with and without flankers.

Authors:  Miguel A García-Pérez; Rocío Alcalá-Quintana; Russell L Woods; Eli Peli
Journal:  Atten Percept Psychophys       Date:  2011-04       Impact factor: 2.199

5.  Improving the estimation of psychometric functions in 2AFC discrimination tasks.

Authors:  Miguel A García-Pérez; Rocío Alcalá-Quintana
Journal:  Front Psychol       Date:  2011-05-11

6.  Visual Contrast Processing is Largely Unaltered during Saccades.

Authors:  Miguel A García-Pérez; Eli Peli
Journal:  Front Psychol       Date:  2011-09-26

7.  Choice of Grating Orientation for Evaluation of Peripheral Vision.

Authors:  Abinaya Priya Venkataraman; Simon Winter; Robert Rosén; Linda Lundström
Journal:  Optom Vis Sci       Date:  2016-06       Impact factor: 1.973

8.  The neural basis of spatial vision losses in the dysfunctional visual system.

Authors:  Jinfeng Huang; Yifeng Zhou; Caiyuan Liu; Zhongjian Liu; Chunmeng Luan; Tzvetomir Tzvetanov
Journal:  Sci Rep       Date:  2017-09-12       Impact factor: 4.379

9.  Aging Potentiates Lateral but Not Local Inhibition of Orientation Processing in Primary Visual Cortex.

Authors:  Zhengchun Wang; Shan Yu; Yu Fu; Tzvetomir Tzvetanov; Yifeng Zhou
Journal:  Front Aging Neurosci       Date:  2018-02-05       Impact factor: 5.750

10.  Are you sure? The relationship between response certainty and performance in visual detection using a perimetry-style task.

Authors:  Phillip Bedggood; Aiza Ahmad; Adam Chen; Rachael Lim; Sadiqa Maqsudi; Andrew Metha
Journal:  J Vis       Date:  2020-08-03       Impact factor: 2.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.