Determination of marine gamma activity and study of the minimum detectable activity (MDA) in 4pi geometry based on Monte Carlo simulation.

C Bagatelas1, C Tsabaris, M Kokkoris, C T Papadopoulos, R Vlastou.   

Abstract

Monte Carlo simulations were performed using the GEANT4 code for the investigation of gamma-ray absorption in water in different spherical geometries and of the efficiency of a NaI(Tl) detector for different radionuclides in the aquatic environment. In order to test the reliability of these simulations, experimental values of the NaI(Tl) detector efficiency were deduced and seem to be in good agreement with the simulated ones. In addition, using the simulated efficiency, an algorithm was developed to determine the minimum detectable activity in becquerels per cubic meter in situ as a function of energy for typical freshwater and seawater spectra.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19421884     DOI: 10.1007/s10661-009-0935-4

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  11 in total

1.  Minimum detectable activity in in situ gamma-ray spectrometry.

Authors:  Y Nir-El; G Haquin
Journal:  Appl Radiat Isot       Date:  2001-08       Impact factor: 1.513

2.  Substrate characterization for underwater gamma spectrometry: tank measurement results utilizing efficiencies calculated via Monte-Carlo code.

Authors:  R Ocone; A Kostezh; V Kurinenko; A Tyshchenko; G Derkach; P Leone
Journal:  Appl Radiat Isot       Date:  2004 Aug-Sep       Impact factor: 1.513

3.  Performance level of an autonomous system of continuous monitoring of radioactivity in seawater.

Authors:  P van Put; A Debauche; C De Lellis; V Adam
Journal:  J Environ Radioact       Date:  2004       Impact factor: 2.674

4.  On line gamma-ray spectrometry at open sea.

Authors:  C Tsabaris; D Ballas
Journal:  Appl Radiat Isot       Date:  2005-01       Impact factor: 1.513

5.  Development of a computer code using the EGS4 Monte Carlo simulation system to evaluate the response of a NaI(Tl) detector to photons with energies below 300 keV.

Authors:  Fayez H H Al-Ghorabie
Journal:  Appl Radiat Isot       Date:  2005-08-24       Impact factor: 1.513

6.  Monte Carlo simulation of gamma-ray spectra from natural radionuclides recorded by a NaI detector in the marine environment.

Authors:  R Vlastou; I Th Ntziou; M Kokkoris; C T Papadopoulos; C Tsabaris
Journal:  Appl Radiat Isot       Date:  2005-09-08       Impact factor: 1.513

7.  Bayesian decision threshold, detection limit and confidence limits in ionising-radiation measurement.

Authors:  K Weise; K Hübel; E Rose; M Schläger; D Schrammel; M Täschner; R Michel
Journal:  Radiat Prot Dosimetry       Date:  2006-07-25       Impact factor: 0.972

8.  An autonomous in situ detection system for radioactivity measurements in the marine environment.

Authors:  C Tsabaris; C Bagatelas; Th Dakladas; C T Papadopoulos; R Vlastou; G T Chronis
Journal:  Appl Radiat Isot       Date:  2008-02-19       Impact factor: 1.513

9.  Monte Carlo calculations of the response features for NaI detectors

Authors: 
Journal:  Appl Radiat Isot       Date:  2000-10       Impact factor: 1.513

10.  Calibration of monitors used for surveillance of radioactivity in effluent water from CERN's accelerator installations.

Authors:  P Vojtyla
Journal:  Appl Radiat Isot       Date:  2001-07       Impact factor: 1.513

View more
  1 in total

1.  Integration of Underwater Radioactivity and Acoustic Sensors into an Open Sea Near Real-Time Multi-Parametric Observation System.

Authors:  Sara Pensieri; Dionisis Patiris; Stylianos Alexakis; Marios N Anagnostou; Aristides Prospathopoulos; Christos Tsabaris; Roberto Bozzano
Journal:  Sensors (Basel)       Date:  2018-08-20       Impact factor: 3.576

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.