Literature DB >> 19421043

Changes in central corneal thickness of preserved corneas over time measured using anterior segment optical coherence tomography.

Chul Young Choi1, Dong Ju Youm, Myoung Joon Kim, Hungwon Tchah.   

Abstract

PURPOSE: To measure central corneal thickness (CCT) and investigate serial changes in CCT, using anterior segment optical coherence tomography (AS-OCT) on corneas in storage medium.
METHODS: Between July and August 2006, 10 human corneoscleral discs from 5 donors between 19 and 57 years of age were obtained. Corneoscleral rims were excised and were transferred to Optisol-GS (Bausch & Lomb, Irvine, CA). After preservation, AS-OCT (Visante OCT; Carl Zeiss Meditec) was performed on all corneoscleral discs to detect serial changes in CCT. The corneas were measured with AS-OCT at 0.5, 1, 2, 3, 4, 6, and 12 hours and then at 1, 2, 3, and 4 days after preservation.
RESULTS: The mean of the baseline CCT measurements obtained with the ultrasound pachymeter was 632.7 microm. The average CCT on AS-OCT decreased to 534 microm in the first day of preservation. As time proceeded, the CCT of each cornea generally decreased. CCT decreased significantly between 30 minutes and 1 hour after preservation (P = 0.004). Also, CCT changes in the interval from preservation to 30 minutes showed a greater decline than during other intervals. Therefore, the most significant change in CCT occurred in the first hour after preservation.
CONCLUSION: AS-OCT offers a fast easy method for evaluating human donor corneas for corneal thickness and structural changes without the risk of bacterial contamination or mechanical damage.

Entities:  

Mesh:

Year:  2009        PMID: 19421043     DOI: 10.1097/ICO.0b013e31819140a9

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  2 in total

Review 1.  Applications of Anterior Segment Optical Coherence Tomography in Cornea and Ocular Surface Diseases.

Authors:  Sang Beom Han; Yu-Chi Liu; Karim Mohamed Noriega; Jodhbir S Mehta
Journal:  J Ophthalmol       Date:  2016-09-19       Impact factor: 1.909

2.  Deformation velocity imaging using optical coherence tomography and its applications to the cornea.

Authors:  Samuel Lawman; Peter W Madden; Vito Romano; Yue Dong; Sharon Mason; Bryan M Williams; Stephen B Kaye; Colin E Willoughby; Simon P Harding; Yao-Chun Shen; Yalin Zheng
Journal:  Biomed Opt Express       Date:  2017-11-13       Impact factor: 3.732

  2 in total