Literature DB >> 19420851

Stability of Loop-Mediated Isothermal Amplification (LAMP) reagents and its amplification efficiency on crude trypanosome DNA templates.

Oriel M M Thekisoe1, Raoul S B Bazie, Andrea M Coronel-Servian, Chihiro Sugimoto, Shin-Ichiro Kawazu, Noboru Inoue.   

Abstract

This study evaluated the stability of LAMP reagents when stored at 25 degrees C and 37 degrees C, and also assessed its detection efficiency on different DNA template preparations. Accordingly, LAMP using reagents stored at 25 degrees C and 37 degrees C amplified DNA of in vitro cultured T. b. brucei (GUTat 3.1) from day 1 to day 15 of reagent storage. There were no significant differences (P>0.05) in detection sensitivity of LAMP among the reagents stored at 25 degrees C, 37 degrees C and -20 degrees C (recommended storage temperature). LAMP using the reagents stored at above-mentioned temperatures amplified serially diluted DNAs (genomic DNA extracted by phenol-chloroform method, FTA card and hemolysed blood) of T. b. gambiense (IL2343) with high sensitivity. Reactions were conducted on the reagents stored from 1 day to 30 days. LAMP detection sensitivity was poor when fresh blood as DNA template was added directly into reactive solution. Results of this study demonstrated that LAMP has the potential to be used in field conditions for diagnosis of trypanosome infections without being affected by ambient temperatures of tropical and sub-tropical countries where trypanosomosis is endemic.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19420851     DOI: 10.1292/jvms.71.471

Source DB:  PubMed          Journal:  J Vet Med Sci        ISSN: 0916-7250            Impact factor:   1.267


  28 in total

1.  The Development of Lyophilized Loop-mediated Isothermal Amplification Reagents for the Detection of Coxiella burnetii.

Authors:  Hua-Wei Chen; Wei-Mei Ching
Journal:  J Vis Exp       Date:  2016-04-18       Impact factor: 1.355

2.  Development of a reverse transcriptase loop-mediated isothermal amplification (LAMP) assay for the sensitive detection of Leishmania parasites in clinical samples.

Authors:  Emily R Adams; Gerard J Schoone; Al Farazdag Ageed; Sayda El Safi; Henk D F H Schallig
Journal:  Am J Trop Med Hyg       Date:  2010-04       Impact factor: 2.345

3.  Prevalence of Trypanosoma sp. in cattle from Tanzania estimated by conventional PCR and loop-mediated isothermal amplification (LAMP).

Authors:  Dusit Laohasinnarong; Oriel M M Thekisoe; Imna Malele; Boniface Namangala; Akihiro Ishii; Yasuyuki Goto; Shin-Ichiro Kawazu; Chihiro Sugimoto; Noboru Inoue
Journal:  Parasitol Res       Date:  2011-07-08       Impact factor: 2.289

4.  Evaluation of a loop-mediated isothermal amplification method as a tool for diagnosis of infection by the zoonotic simian malaria parasite Plasmodium knowlesi.

Authors:  Hiroshi Iseki; Satoru Kawai; Nobuyuki Takahashi; Makoto Hirai; Kazuyuki Tanabe; Naoaki Yokoyama; Ikuo Igarashi
Journal:  J Clin Microbiol       Date:  2010-05-05       Impact factor: 5.948

5.  Detection of Trypanosoma cruzi and T. rangeli infections from Rhodnius pallescens bugs by loop-mediated isothermal amplification (LAMP).

Authors:  Oriel M M Thekisoe; Carol V Rodriguez; Francisco Rivas; Andrea M Coronel-Servian; Shinya Fukumoto; Chihiro Sugimoto; Shin-Ichiro Kawazu; Noboru Inoue
Journal:  Am J Trop Med Hyg       Date:  2010-05       Impact factor: 2.345

Review 6.  An overview of methods/techniques for the detection of Cryptosporidium in food samples.

Authors:  Shahira A Ahmed; Panagiotis Karanis
Journal:  Parasitol Res       Date:  2018-01-19       Impact factor: 2.289

7.  Development and Assessment of Leishmania major and Leishmania tropica Specific Loop-Mediated Isothermal Amplification Assays for the Diagnosis of Cutaneous Leishmaniasis in Tunisia.

Authors:  Melek Chaouch; Karim Aoun; Souad Ben Othman; Meriem Ben Abid; Ines Ben Sghaier; Aida Bouratbine; Souha Ben Abderrazak
Journal:  Am J Trop Med Hyg       Date:  2019-07       Impact factor: 2.345

8.  A loop-mediated isothermal amplification (LAMP) assay for Strongyloides stercoralis in stool that uses a visual detection method with SYTO-82 fluorescent dye.

Authors:  Matthew R Watts; Gregory James; Yasmin Sultana; Andrew N Ginn; Alexander C Outhred; Fanrong Kong; Jaco J Verweij; Jonathan R Iredell; Sharon C-A Chen; Rogan Lee
Journal:  Am J Trop Med Hyg       Date:  2013-12-09       Impact factor: 2.345

9.  Development of loop-mediated isothermal amplification (LAMP) assays for rapid detection of Ehrlichia ruminantium.

Authors:  Ryo Nakao; Ellen Y Stromdahl; Joseph W Magona; Bonto Faburay; Boniface Namangala; Imna Malele; Noboru Inoue; Dirk Geysen; Kiichi Kajino; Frans Jongejan; Chihiro Sugimoto
Journal:  BMC Microbiol       Date:  2010-11-19       Impact factor: 3.605

10.  Comparison of a loop-mediated isothermal amplification for orf virus with quantitative real-time PCR.

Authors:  Guangxiang Wang; Youjun Shang; Yanhua Wang; Hong Tian; Xiangtao Liu
Journal:  Virol J       Date:  2013-05-01       Impact factor: 4.099

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.