Pressure volume curves of paediatric laryngeal mask airways.

C J Wallace1, N A Chambers, T O Erb, B S von Ungern-Sternberg.   

Abstract

Hyperinflation of the laryngeal mask airway cuff may exert high pressure on pharyngeal and laryngeal structures. In vitro data show that high intra cuff pressures may occur when inflated to only 30% of the manufacturer's recommended maximum inflation volume. We prospectively assessed the pressure volume curves of paediatric sized laryngeal mask airways (size 1-3) in 240 consecutive children (0-15 years). Following laryngeal mask airway insertion the cuff was inflated with 1-ml increments of air up to the maximum recommended by the manufacturer. After each ml cuff pressure was measured. At the end all cuff pressures were adjusted to 55 cmH(2)O. The maximum recommended volume resulted in high intracuff pressures in all laryngeal mask airway brands and sizes studied. Approximately half the maximum volume produced a cuff pressure > or = 60 cmH(2)O. This occurred in all brands and all sizes studied. We recommend that cuff manometers should be used to guide inflation in paediatric laryngeal mask airways.

Entities:  

Mesh:

Year:  2009        PMID: 19413823     DOI: 10.1111/j.1365-2044.2008.05819.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  6 in total

1.  Recent advances in airway management in children.

Authors:  Francis Veyckemans
Journal:  F1000 Med Rep       Date:  2009-09-28

2.  [Continuous cuff pressure measurement during laryngeal mask anesthesia : An obligatory measure to avoid postoperative complications].

Authors:  M Hensel; T Güldenpfennig; A Schmidt; M Krumm
Journal:  Anaesthesist       Date:  2016-04-12       Impact factor: 1.041

3.  A simple method of partial inflation of the LMA cuff before insertion in children to allow cuff pressure without adjustment after insertion.

Authors:  Bo-Eun Moon; Min-Soo Kim; Jeong Rim Lee
Journal:  Korean J Anesthesiol       Date:  2012-06-19

4.  Comparison of effects of ProSeal LMA™ laryngeal mask airway cuff inflation with air, oxygen, air:oxygen mixture and oxygen:nitrous oxide mixture in adults: A randomised, double-blind study.

Authors:  Mona Sharma; Renu Sinha; Anjan Trikha; Rashmi Ramachandran; C Chandralekha
Journal:  Indian J Anaesth       Date:  2016-08

5.  Correlation and variation of cuff inflating volumes and pressures in different adult models of laryngeal mask: a prospective randomized trial.

Authors:  Narut Ruananukun; Jittiya Watcharotayangul; Suchaya Jeeranukosol; Rojnarin Komonhirun
Journal:  BMC Anesthesiol       Date:  2020-05-07       Impact factor: 2.217

6.  Application of Minimum Effective Cuff Inflating Volume for Laryngeal Mask Airway and its Impact on Postoperative Pharyngeal Complications.

Authors:  Bing-Bing Li; Jie Yan; Hong-Gang Zhou; Jing Hao; Ai-Jia Liu; Zheng-Liang Ma
Journal:  Chin Med J (Engl)       Date:  2015-10-05       Impact factor: 2.628

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.