Literature DB >> 19413335

Investigation of the effect of the extraction phase geometry on the performance of automated solid-phase microextraction.

Erasmus Cudjoe1, Dajana Vuckovic, Dietmar Hein, Janusz Pawliszyn.   

Abstract

A new configuration of C(18) thin film extraction phase designed for high sample throughput has been developed and applied to the analysis of benzodiazepines in spiked urine samples using high performance liquid chromatography coupled with tandem mass spectrometry. The high throughput analysis was achieved with the use of a robotic autosampler which enabled parallel analyte extraction in a 96-well plate format. Factors affecting data reproducibility, extraction kinetics, sample throughput, and reliability of the system were investigated and optimized. The intrawell reproducibility was 4.5-7.3%, while interwell reproducibility was 7.0-11% in urine and PBS samples. The limits of detection and quantitation were 0.05-0.15 ng/mL and 0.2-2.0 ng/mL for all analytes, respectively. By comparison with optimized automated multifiber SPME relying on rod geometry, the C(18) thin films showed higher extraction rates (approximate 2-fold increase) and hence higher sample throughput because of the improved configuration and more effective agitation/mass transfer. In addition, this new configuration provided an extraction phase with greater surface area to volume ratio and greater extraction phase volume, which resulted in approximately 2-fold increase in the extraction capacity for diazepam compared with the extractions with automated multifiber SPME rod geometry. The results of this investigation demonstrated the advantages of using thin films to improve extraction kinetics and sensitivity of automated SPME methods for high performance liquid chromatography.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19413335     DOI: 10.1021/ac802524w

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  Automated solid-phase microextraction and thin-film microextraction for high-throughput analysis of biological fluids and ligand-receptor binding studies.

Authors:  Dajana Vuckovic; Erasmus Cudjoe; Florin Marcel Musteata; Janusz Pawliszyn
Journal:  Nat Protoc       Date:  2010-01-07       Impact factor: 13.491

2.  Modifying current thin-film microextraction (TFME) solutions for analyzing prohibited substances: Evaluating new coatings using liquid chromatography.

Authors:  Łukasz Sobczak; Dominika Kołodziej; Krzysztof Goryński
Journal:  J Pharm Anal       Date:  2022-01-04

3.  Systematic Evaluation of Different Coating Chemistries Used in Thin-Film Microextraction.

Authors:  Jia-Wei Liu; Khaled Murtada; Nathaly Reyes-Garcés; Janusz Pawliszyn
Journal:  Molecules       Date:  2020-07-29       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.