Fatigue failure of the sliding screw in hip fracture fixation: a report of three cases.

J M Spivak1, J D Zuckerman, F J Kummer, V H Frankel.   

Abstract

Hardware failure of the sliding screw system used in hip fracture fixation is rare. The fatigue failure of the sliding screw is always related clinically to nonunion or refracture along the path of the screw. In both situations, cyclic loading of the implant exceeds its endurance limit, and failure can ensue. Three cases of failure of the sliding screw are presented: a nonunion of a basicervical fracture, a nonunion secondary to stress fracture at the plate-barrel junction, and a refracture through the femoral neck after healing of an intertrochanteric fracture. A biomechanical analysis of the stresses on the sliding screw focuses on design features such as the internal threaded region used for the compression screw or the barrel length that creates increased stresses in the screw, thus lowering the number of cycles to failure. Based on this analysis, recommendations are made concerning implant design and surgical technique.

Entities:  

Mesh:

Year:  1991        PMID: 1941316     DOI: 10.1097/00005131-199109000-00012

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  6 in total

1.  Comparison of stable and unstable pertrochanteric femur fractures managed with 2- and 4-hole side plates.

Authors:  Robert P Baird; Peter O'Brien; David Cruickshank
Journal:  Can J Surg       Date:  2014-10       Impact factor: 2.089

2.  Type II Intertrochanteric Fractures: Proximal Femoral Nailing (PFN) Versus Dynamic Hip Screw (DHS).

Authors:  Cyril Jonnes; Shishir Sm; Syed Najimudeen
Journal:  Arch Bone Jt Surg       Date:  2016-01

3.  Comparative prospective study of proximal femoral nail and dynamic hip screw in treatment of intertrochanteric fracture femur.

Authors:  Ranjeetesh Kumar; R N Singh; B N Singh
Journal:  J Clin Orthop Trauma       Date:  2012-06-16

4.  Unusual mode of failure of intertrochanteric femur fracture fixation.

Authors:  Kunal Roy; Pradip Nemade; Rishi Aggarwal; Nirmal Patil
Journal:  BMJ Case Rep       Date:  2015-11-12

5.  Role of Provisional Fixation of Fracture Fragments By Steinmann-Pin and Technical Tips in Proximal Femoral Nailing for Intertrochanteric Fracture.

Authors:  Mohit J Jain; Kinjal J Mavani; Dhaval Patel
Journal:  J Clin Diagn Res       Date:  2017-06-01

6.  Incredible position of broken sliding dynamic hip screw implant in the medial of thigh.

Authors:  Saeed Solooki; Amir Reza Vosoughi
Journal:  Acta Orthop Traumatol Turc       Date:  2017-04-25       Impact factor: 1.511

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.