Literature DB >> 1941142

Infectious imaging with indium-111-labeled nonspecific polyclonal human immunoglobulin.

W A Wegener1, M G Velchik, D Weiss, S Ter, A Byars, M Neptune, A Alavi.   

Abstract

Nonspecific polyclonal immunoglobulin (IgG), prepared from pooled human serum gamma globulin and labeled with 111In has been reported to be equivalent to antigen-specific antibody in the detection of focal infection or inflammation during the first 24 hr after injection. We describe our experience in a Phase II clinical study using 111In-IgG in 15 patients (8 males, 7 females) ranging from 26 to 80 (mean = 50) yr of age with suspected focal infection/inflammation. Pathologic confirmation was obtained in 5/15 cases. A combination of clinical course, laboratory results, and other imaging procedures were used to categorize the other 10 patients. One possible false-negative involved a presumed aspiration pneumonia in a patient with a history of aspiration, bibasilar infiltrates on chest film, and no other identified source of infection. Otherwise, there were 10 confirmed positives, 4 confirmed negatives, and no false-positives. Our findings confirm earlier reports that 111In-IgG may be a superior imaging agent for infection/inflammation with practical advantages over 67Ga-citrate and 111In-labeled leukocytes.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1941142

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  4 in total

1.  Imaging inflammation with human polyclonal immunoglobulin: not looked for but discovered.

Authors:  F H Corstens; R A Claessens
Journal:  Eur J Nucl Med       Date:  1992

2.  Technetium-99m labelling of human immunoglobulin and preliminary clinical evaluation in tumour patients.

Authors:  A D Varvarigou; S C Archimandritis; A Stripsanelli; A Arka; P Kostamis
Journal:  Eur J Drug Metab Pharmacokinet       Date:  1998 Apr-Jun       Impact factor: 2.441

3.  Immunoscintigraphy with antigranulocyte monoclonal antibodies for the diagnosis of septic loosening of hip prostheses.

Authors:  A Boubaker; A B Delaloye; C H Blanc; M Dutoit; P F Leyvraz; B Delaloye
Journal:  Eur J Nucl Med       Date:  1995-02

4.  Immunoscintigraphy in the detection of tuberculosis with radiolabelled antibody fragment against Mycobacterium bovis bacillus Calmette-Guérin: a preliminary study in a rabbit model.

Authors:  J D Lee; K H Shin; S N Cho; J S Shin; M G Lee; W I Yang; C Y Park; H S Yoo; J T Lee; O D Awh
Journal:  Eur J Nucl Med       Date:  1992
  4 in total