Literature DB >> 19410406

320-multidetector row whole-head dynamic subtracted CT angiography and whole-brain CT perfusion before and after carotid artery stenting: technical note.

Diego San Millán Ruíz1, Kieran Murphy, Philippe Gailloud.   

Abstract

INTRODUCTION: Multidetector CT (MDCT) is increasingly used for the investigation of neurovascular disorders, but restricted z-axis coverage (3.2 cm for 64-MDCT) currently limits perfusion to a small portion of the brain close to the circle of Willis, and precludes dynamic angiographic appreciation of the entire brain circulation. We illustrate the clinical potential of recently developed 320-MDCT extending the z-axis coverage to 16 cm in a patient with symptomatic carotid artery stenosis.
METHODS: In a 74-year-old patient presenting with critical symptomatic stenosis of the left CCA, pre- and post-carotid artery stenting whole-head subtracted dynamic MDCT angiography and perfusion were obtained in addition to CT angiography of the supra-aortic trunks. Both whole-head subtracted MDCT angiography and perfusion demonstrated delayed left ICA circulation, which normalized after carotid stenting. DISCUSSION: 320-MDCT offers unprecedented z-axis coverage allowing for whole-brain perfusion and subtracted dynamic angiography of the entire intracranial circulation. These innovations can consolidate the role of MDCT as a first intention imaging technique for cerebrovascular disorders, in particular for the acute management of stroke. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 19410406     DOI: 10.1016/j.ejrad.2009.03.015

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  6 in total

1.  Dynamic CT angiography and CT perfusion employing a 320-detector row CT: protocol and current clinical applications.

Authors:  Eric J Salomon; Joe Barfett; Peter W A Willems; Sasikhan Geibprasert; Susanna Bacigaluppi; Timo Krings
Journal:  Klin Neuroradiol       Date:  2009-08-23

2.  The role of 4D CT angiography for preoperative screening in patients with intracranial tumors.

Authors:  Kazufumi Suzuki; Kayoko Abe; Takashi Maruyama; Masayuki Nitta; Kosaku Amano; Koji Yamaguchi; Takakazu Kawamata; Shuji Sakai
Journal:  Neuroradiol J       Date:  2016-03-11

Review 3.  Computed tomography in acute ischemic stroke.

Authors:  Karl-Olof Lövblad; Alison E Baird
Journal:  Neuroradiology       Date:  2009-12-02       Impact factor: 2.804

4.  How Low Can We Go in Radiation Dose for the Data-Completion Scan on a Research Whole-Body Photon-Counting Computed Tomography System.

Authors:  Zhicong Yu; Shuai Leng; Zhoubo Li; Ahmed F Halaweish; Steffen Kappler; Erik L Ritman; Cynthia H McCollough
Journal:  J Comput Assist Tomogr       Date:  2016 Jul-Aug       Impact factor: 1.826

5.  First experience of efficacy and radiation exposure in 320-detector row CT fluoroscopy-guided interventions.

Authors:  Shota Yamamoto; Tomohiro Matsumoto; Satoshi Suda; Kosuke Tomita; Shunsuke Kamei; Kazunobu Hashida; Yutaka Imai; Kazuyuki Endo; Katsuki Murakami; Terumitsu Hasebe
Journal:  Br J Radiol       Date:  2021-02-05       Impact factor: 3.039

6.  Evaluating the morphological changes of intracranial arteries and whole-brain perfusion in undetermined isolated vertigo.

Authors:  Wenxian Li; Youzhen Feng; Weibiao Lu; Xie Xie; Zhilin Xiong; Zhen Jing; Xiangran Cai; Li'an Huang
Journal:  J Neurol Sci       Date:  2016-09-14       Impact factor: 3.181

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.