Literature DB >> 19410264

Magnetic stimulation of the cauda equina in the spinal canal with a flat, large round coil.

Hideyuki Matsumoto1, Fitri Octaviana, Yasuo Terao, Ritsuko Hanajima, Akihiro Yugeta, Masashi Hamada, Satomi Inomata-Terada, Setsu Nakatani-Enomoto, Shoji Tsuji, Yoshikazu Ugawa.   

Abstract

Magnetic round coil stimulation over the spinal enlargement activates the spinal nerves at the neuro-foramina level. However, activation of the cauda equina in the spinal canal has never been described in the literature. This study, for which 40 healthy subjects were recruited, activated the cauda equina using a round 20-cm-diameter coil designated as a Magnetic Augmented Translumbosacral Stimulation (MATS) coil. Magnetic stimulation placing the edge of the coil over the L1 and L3 spinous processes elicited compound muscle action potentials (CMAPs) from the abductor hallucis muscle. The CMAPs were compared with those elicited through high-voltage electrical stimulation. The CMAP latencies to L1 level MATS coil stimulation were not significantly different from those evoked by electrical stimulation at the same level. The CMAP latencies to L3 level MATS coil stimulation were varied in each subject. In fact, the L1 level MATS coil stimulation is considered to activate the cauda equina at the root exit site from the conus medullaris; the L3 level MATS coil stimulation activates some mid-part of the cauda equina or the distal cauda equina by spreading current. The MATS coil facilitates evaluation of spinal nerve conduction in the cauda equina.

Entities:  

Mesh:

Year:  2009        PMID: 19410264     DOI: 10.1016/j.jns.2009.04.003

Source DB:  PubMed          Journal:  J Neurol Sci        ISSN: 0022-510X            Impact factor:   3.181


  4 in total

1.  Neurophysiological analysis of the cauda equina in POEMS syndrome.

Authors:  Hideyuki Matsumoto; Ritsuko Hanajima; Yasuo Terao; Hideji Hashida; Yoshikazu Ugawa
Journal:  Neurol Sci       Date:  2012-01-19       Impact factor: 3.307

2.  Motor cortical excitability in peritoneal dialysis: a single-pulse TMS study.

Authors:  Hideyuki Matsumoto; Katsunori Saito; Yuko Konoma; Shingo Okabe; Yoshikazu Ugawa; Yoshitaka Ishibashi
Journal:  J Physiol Sci       Date:  2014-11-07       Impact factor: 2.781

3.  Translumbar and transsacral magnetic neurostimulation for the assessment of neuropathy in fecal incontinence.

Authors:  Satish S C Rao; Enrique Coss-Adame; Kasaya Tantiphlachiva; Ashok Attaluri; Jose Remes-Troche
Journal:  Dis Colon Rectum       Date:  2014-05       Impact factor: 4.585

4.  A multiple regression model of normal central and peripheral motor conduction times.

Authors:  Stephan R Jaiser; Jonathan D Barnes; Stuart N Baker; Mark R Baker
Journal:  Muscle Nerve       Date:  2015-03-14       Impact factor: 3.217

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.