Literature DB >> 19409022

Ultrasound-aided fixation of a biodegradable cranial fixation system: uses in pediatric neurosurgery.

Philipp R Aldana1, Saswata Roy, Richard A Postlethwait, Hector E James.   

Abstract

OBJECT: Bioresorbable implant systems have been used in neurosurgery for the rigid fixation of cranial and facial bones. A relatively recent advancement has been the fixation of these implants using an ultrasonic device. The experience with such a device in neurosurgical practice has been limited. The authors report on their experience with ultrasound-aided fixation of bioresorbable implants in pediatric neurosurgical practice.
METHODS: The study consisted of 2 parts. The retrospective portion consisted of a chart review of pertinent clinical information, complications, and outcomes after the use of a commercially available ultrasound-aided bioresorbable implant system (SonicWeld Rx, KLS Martin L.P.). Follow-up was obtained in all patients via clinical examination or telephone interview. The prospective portion of the study consisted of video analysis of the implantation technique in a routine craniotomy. Implantation times were measured, and delays during treatment were noted.
RESULTS: Over a period of 2 years, 28 consecutive patients underwent placement of these implants for bone fixation during craniotomies or craniofacial reconstructions. The only complication was seen in a child with Crouzon syndrome, who had a wound infection caused by Serratia sepsis from a central venous line infection. There were no repeated operations for implant-related swelling, and no cases of premature plate resorption, bone instability, or settling. In vivo, the average time required to implant a resorbable pin with this system was 22 seconds.
CONCLUSIONS: The use of a bioresorbable implant system with ultrasound-aided pin fixation in pediatric neurosurgery cases achieved adequate stability with few complications. This system was easy to use and provided rapid fixation of implants.

Entities:  

Mesh:

Year:  2009        PMID: 19409022     DOI: 10.3171/2009.2.PEDS08230

Source DB:  PubMed          Journal:  J Neurosurg Pediatr        ISSN: 1933-0707            Impact factor:   2.375


  5 in total

1.  Experience with resorbable sonic pins for the attachment of distraction devices in posterior cranial vault distraction operations.

Authors:  Leonid Satanin; Ivan Teterin; Alexander Sakharov; Vitaly Roginsky; Willy Serlo; Niina Salokorpi
Journal:  Childs Nerv Syst       Date:  2019-03-08       Impact factor: 1.475

2.  The clinical usefulness of ultrasound-aided fixation using an absorbable plate system in patients with zygomatico-maxillary fracture.

Authors:  Jong Hun Lee; Jun Hyung Park
Journal:  Arch Plast Surg       Date:  2013-07-17

3.  Ultrasonically assisted anchoring of biodegradable implants for chevron osteotomies - clinical evaluation of a novel fixation method.

Authors:  Kai Olms; Thorsten Randt; Nils Reimers; Nils Zander; Arndt P Schulz
Journal:  Open Orthop J       Date:  2014-04-24

4.  Bioresorbable plate fracture after cranioplasty caused by head injury: a pediatric case.

Authors:  Kohei Igarashi; Atsushi Kuge; Hiroshi Homma; Tetsu Yamaki; Rei Kondo; Shinjiro Saito; Yukihiko Sonoda
Journal:  Int J Emerg Med       Date:  2021-12-20

Review 5.  Titanium or Biodegradable Osteosynthesis in Maxillofacial Surgery? In Vitro and In Vivo Performances.

Authors:  Barzi Gareb; Nico B Van Bakelen; Arjan Vissink; Ruud R M Bos; Baucke Van Minnen
Journal:  Polymers (Basel)       Date:  2022-07-07       Impact factor: 4.967

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.