Literature DB >> 19406573

Synthesis of a novel chelating resin and its use for selective separation and preconcentration of some trace metals in water samples.

Serife Tokalioğlu1, Vedat Yilmaz, Senol Kartal, Ali Delibaş, Cengiz Soykan.   

Abstract

A new chelating resin, poly[N-(4-bromophenyl)-2-methacrylamide-co-2-acrylamido-2-methyl-1-propanesulfonic acid-co-divinylbenzene], was synthesized and characterized. The resin was used for selective separation, preconcentration and determination of Cu(II), Ni(II), Co(II), Cd(II), Pb(II), Mn(II) and Fe(III) ions in water samples by flame atomic absorption spectrometry. Effects of pH, concentration and volume of elution solution, sample flow rate, sample volume and interfering ions (Na(+), K(+), Ca(2+), Mg(2+), Fe(3+), Mn(2+), Al(3+), Zn(2+), Pb(2+), Cu(2+), Ni(2+), Cd(2+), Cl(-) and SO(4)(2-)) on the recovery of the analytes were investigated. The sorption capacity of the resin was 25.6, 19.8, 32.1, 41.3, 38.9, 13.9 and 18.3 mg g(-1) for Cu(II), Ni(II), Co(II), Cd(II), Pb(II), Mn(II) and Fe(III), respectively. A high preconcentration factor, 100, and low relative standard deviation, <or=2.5% (n=7) values were obtained. The detection limits (microg L(-1)) were 0.57 for Cu(II), 0.37 for Ni(II), 0.24 for Co(II), 0.09 for Cd(II), 1.6 for Pb(II), 0.19 for Mn(II) and 0.72 for Fe(III). The method was validated by analysing fortified lake water (TMDA-54.4, a trace element fortified calibration standard) and spiked water samples. The method was applied to the determination of the analytes in tap and lake water samples.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19406573     DOI: 10.1016/j.jhazmat.2009.03.146

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  3 in total

1.  The use of silica gel modified with allyl 6-methyl-4-phenyl-2-thioxo-1,2,3,4-tetrahydropyrimidine-5-carboxylate for selective separation and preconcentration of lead in environmental samples.

Authors:  Fatemeh Sabermahani; Zahra Hassani; Mahboobeh Faramarzpoor
Journal:  Environ Monit Assess       Date:  2012-10-06       Impact factor: 2.513

2.  Novel solid-phase extractor based on functionalization of multi-walled carbon nano tubes with 5-aminosalicylic acid for preconcentration of Pb(II) in water samples prior to determination by ICP-OES.

Authors:  Ezzat M Soliman; Hadi M Marwani; Hassan M Albishri
Journal:  Environ Monit Assess       Date:  2013-07-07       Impact factor: 2.513

3.  Selective Iron(III) ion uptake using CuO-TiO2 nanostructure by inductively coupled plasma-optical emission spectrometry.

Authors:  Mohammed M Rahman; Sher Bahadar Khan; Hadi M Marwani; Abdullah M Asiri; Khalid A Alamry
Journal:  Chem Cent J       Date:  2012-12-17       Impact factor: 4.215

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.