Literature DB >> 19405774

Three-wavelength technique for the measurement of oxygen saturation in arterial blood and in venous blood.

Meir Nitzan1, Shlomo Engelberg.   

Abstract

Pulse oximetry is an optical technique for the assessment of oxygen saturation in arterial blood and is based on the different light absorption spectra for oxygenated and deoxygenated hemoglobin and on two-wavelength photoplethysmographic (PPG) measurement of arterial blood volume increase during systole. The technique requires experimental calibration for the determination of the relationship between PPG-derived parameters and arterial oxygen saturation, and this calibration is a source of error in the method. We suggest a three-wavelength PPG technique for the measurement of arterial oxygen saturation that has no need for calibration if the three wavelengths are properly selected in the near-infrared region. The suggested technique can also be implemented for the assessment of venous oxygen saturation by measuring the decrease in transmission of light through a tissue after increasing its blood volume by venous occlusion. The oxygen saturation in venous blood is a parameter that is related to oxygen consumption in tissue and to tissue blood flow. The three-wavelength method has the potential to provide accurate oxygen saturation measurements in arterial and venous blood, but experimental validation of the theory is still required to confirm this claim.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19405774     DOI: 10.1117/1.3120496

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  7 in total

1.  Experimental system for measuring the full scattering profile of circular phantoms.

Authors:  Idit Feder; Hamootal Duadi; Dror Fixler
Journal:  Biomed Opt Express       Date:  2015-07-14       Impact factor: 3.732

2.  Hyperspectral imaging fluorescence excitation scanning for colon cancer detection.

Authors:  Silas J Leavesley; Mikayla Walters; Carmen Lopez; Thomas Baker; Peter F Favreau; Thomas C Rich; Paul F Rider; Carole W Boudreaux
Journal:  J Biomed Opt       Date:  2016-10-01       Impact factor: 3.170

3.  Developing a Wireless, High Precision and Processing Speed Pulse Monitoring Headset Using Photoplethysmography.

Authors:  Yunhui Jiang; Jian Tang; Xiaoliang Wang; Chao Shen
Journal:  IEEE J Transl Eng Health Med       Date:  2017-10-20       Impact factor: 3.316

4.  A novel method based on two cameras for accurate estimation of arterial oxygen saturation.

Authors:  He Liu; Kamen Ivanov; Yadong Wang; Lei Wang
Journal:  Biomed Eng Online       Date:  2015-05-30       Impact factor: 2.819

5.  Calibration-free pulse oximetry based on two wavelengths in the infrared - a preliminary study.

Authors:  Meir Nitzan; Salman Noach; Elias Tobal; Yair Adar; Yaacov Miller; Eran Shalom; Shlomo Engelberg
Journal:  Sensors (Basel)       Date:  2014-04-23       Impact factor: 3.576

Review 6.  Noninvasive hemoglobin sensing and imaging: optical tools for disease diagnosis.

Authors:  Michaela Taylor-Williams; Graham Spicer; Gemma Bale; Sarah E Bohndiek
Journal:  J Biomed Opt       Date:  2022-08       Impact factor: 3.758

Review 7.  Pulse oximetry: fundamentals and technology update.

Authors:  Meir Nitzan; Ayal Romem; Robert Koppel
Journal:  Med Devices (Auckl)       Date:  2014-07-08
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.