Literature DB >> 19403517

Fixed-diameter scan protocol preferable for retinal nerve fibre layer measurement by optical coherence tomography in all sizes of optic discs.

S Kaushik1, S S Pandav, P Ichhpujani, A Gupta.   

Abstract

BACKGROUND: Retinal nerve fibre layer (RNFL) measurements using a fixed-diameter versus a user-defined scan-protocol of optical coherence tomography (Stratus OCT) were compared in 32 normal, 62 glaucoma suspects and 36 glaucomatous eyes.
METHODS: Peripapillary RNFL thickness was measured using the standard "fast" RNFL scan-protocol and proportional 2.27 x disc scan protocol. Disc size was measured using the "fast" optic disc protocol. The correlation between RNFL thickness for each scan-protocol and disc size was analysed.
RESULTS: In normal eyes, RNFL thickness was independent of the optic-disc area using the fixed-diameter protocol (p = 0.92) but was inversely proportional to disc size using the proportional protocol (p<0.001). In glaucoma suspects, the optic-disc area correlated with RNFL thickness using the fixed-diameter protocol (p<0.001). In the multivariate analysis in glaucomatous eyes, the RNFL thickness using the fixed-diameter protocol was significantly affected by the mean deviation on visual fields but not by disc area (p<0.001 and p = 0.64 respectively)
CONCLUSION: In normal subjects, disc size does not appear to affect RNFL measurements by OCT using the fixed-diameter protocol, thus indicating that RNFL thickness may be related to distance from the centre of the optic disc rather than the margin. The thicker RNFL observed in large glaucomatous discs in this study may be related to the earlier stage of glaucoma, though it may not apply to the general population.

Entities:  

Mesh:

Year:  2009        PMID: 19403517     DOI: 10.1136/bjo.2008.148387

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  4 in total

1.  Retinal Nerve Fiber Layer Thicknesses in Three Different Optic Nerve Head Size Groups Measured by Cirrus Spectral Domain Optical Coherence Tomography.

Authors:  Sirel Gür Güngör; Ahmet Akman; Ali Küçüködük; Meriç Çolak
Journal:  Turk J Ophthalmol       Date:  2016-04-05

2.  New Circumpapillary Retinal Nerve Fiber Layer Thickness and Bruch's Membrane Opening-Minimum Rim Width Assessment in Nonglaucomatous Eyes with Large Discs.

Authors:  Serife Bayraktar; Gulnar Sultanova; Zafer Cebeci; Emre Altinkurt; Belgin Izgi
Journal:  J Ophthalmol       Date:  2019-10-23       Impact factor: 1.909

3.  A Wide-Field Optical Coherence Tomography Normative Database Considering the Fovea-Disc Relationship for Glaucoma Detection.

Authors:  Hyungjun Kim; Jong Sub Lee; Hae Min Park; Hyunsoo Cho; Han Woong Lim; Mincheol Seong; Junhong Park; Won June Lee
Journal:  Transl Vis Sci Technol       Date:  2021-02-05       Impact factor: 3.283

4.  Influence of disc area on retinal nerve fiber layer thickness measurement by spectral domain optical coherence tomography.

Authors:  Tarannum Mansoori; Nagalla Balakrishna; Kalluri Viswanath
Journal:  Indian J Ophthalmol       Date:  2014-05       Impact factor: 1.848

  4 in total