Literature DB >> 19402146

Wear and hardness of different core build-up materials.

Petra Schmage1, Ibrahim Nergiz, Fekry Sito, Ursula Platzer, Martin Rosentritt.   

Abstract

Before crown preparation, teeth with extensive coronal destructions are built up with core materials. Sometimes, these build ups are exposed to the oral environment without the protection of crowns. Therefore, this in vitro investigation was aimed at evaluating the wear, surface roughness, Vickers hardness, and surface structure of 10 core composites, two glass ionomer cements (GICs), and four posterior restoration composites. The three-body wear was tested after water storage and 2,00,000 cycles. We measured both surface roughness and Vickers hardness (DIN 50133) and evaluated the surface structures by scanning electron microscopy. Results were statistically analyzed by use of the Mann-Whitney U test (alpha = 0.05). Lowest wear was found for the restorative composites (20 microm Grandio; others about 40 microm). A comparison of the composites Build-It, Chroma Core, Rebilda LC, and Rebilda DC to Quixfil showed similar wear values for each material (43-50 microm). Wear values of GICs and all others core composites ranged between 58 and 75 microm. Only Ti-Core showed significantly higher wear than all other materials (p < 0.05). All core materials except Ti-Core (35 HV) showed Vickers hardness values between 42 and 61 HV. Most core composites, particularly Build-It, Multicore Flow, Rebilda LC, Ecusit, and Tetric Evo Ceram, showed more homogenous surface structures compared to GICs and restorative composites. Therefore, wear values of core build-up materials not only differed widely but were higher than those of conventional restorative materials; yet, core build-up materials showed advantageous surface structures. (c) 2009 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19402146     DOI: 10.1002/jbm.b.31375

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  4 in total

1.  Are resin composites suitable replacements for amalgam? A study of two-body wear.

Authors:  Dimitra Lazaridou; Renan Belli; Anselm Petschelt; Ulrich Lohbauer
Journal:  Clin Oral Investig       Date:  2014-12-10       Impact factor: 3.573

2.  Physical properties of self-, dual-, and light-cured direct core materials.

Authors:  Stefan Rüttermann; Ian Alberts; Wolfgang H M Raab; Ralf R Janda
Journal:  Clin Oral Investig       Date:  2010-04-07       Impact factor: 3.573

3.  Early failures when using three different adhesively retained core build-up materials-a randomized controlled trial.

Authors:  Andreas Zenthöfer; Justo Lorenzo Bermejo; Wolfgang Bömicke; Cornelia Frese; Rumeysa Gülmez; Peter Rammelsberg; Brigitte Ohlmann
Journal:  Clin Oral Investig       Date:  2021-09-07       Impact factor: 3.573

4.  Clinical performance of a new biomimetic double network material.

Authors:  Christine Dirxen; Uwe Blunck; Saskia Preissner
Journal:  Open Dent J       Date:  2013-09-06
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.