Literature DB >> 19399077

Practical methods for retrace error correction in nonnull aspheric testing.

Dong Liu1, Yongying Yang, Chao Tian, Yongjie Luo, Lin Wang.   

Abstract

Nonnull test is often adopted for aspheric testing. But due to its violation of null condition, the testing rays will follow different paths from the reference and aberrations from the interferometer will not cancel out, leading to widely difference between the obtained surface figure and that of the real, which is called the Retrace-error accordingly. In this paper, retrace error of nonnull aspheric testing is analyzed in detail with conclusions that retrace error has much to do with the aperture, F number and surface shape error of the aspheric under test. Correcting methods are proposed according to the manner of the retrace errors. Both computer simulation and experimental results show that the proposed methods can correct the retrace error effectively. The analysis and proposed correction methods bring much to the application of nonnull aspheric testing.

Entities:  

Mesh:

Year:  2009        PMID: 19399077     DOI: 10.1364/oe.17.007025

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  1 in total

1.  Multi-Field Interference Simultaneously Imaging on Single Image for Dynamic Surface Measurement.

Authors:  Weiqiang Han; Xiaodong Gao; Zhen Chen; Le Bai; Bo Liu; Rujin Zhao
Journal:  Sensors (Basel)       Date:  2020-06-15       Impact factor: 3.576

  1 in total