Literature DB >> 19395458

Ultraviolet light output of compact fluorescent lamps: comparison to conventional incandescent and halogen residential lighting sources.

A D Nuzum-Keim1, R D Sontheimer.   

Abstract

Patients with photosensitive dermatologic and systemic diseases often question the ultraviolet light (UVL) output of household lighting sources. Such individuals have increasing concern about potential UVL exposure from energy-efficient compact fluorescent lamps (CFL), as little data have been presented concerning their UVL output. The objective was to compare, via pilot study, the levels of ultraviolet A (UVA) and ultraviolet B (UVB) leak between residential lighting sources. Equivalent wattage CFL, incandescent and halogen bulbs were purchased from local retailers in Oklahoma City, Oklahoma, USA. The UVA and UVB outputs of these sources were measured under controlled conditions at 10, 25, 50, 100 and 150 cm away from the light source using an IL-1700 research radiometer equipped with UVA and UVB detectors. Negligible UVB and UVA was detected at 100 and 150 cm. Therefore, data were analysed from measurements at 10, 25 and 50 cm only. The results demonstrated UVA leak highest from incandescent and halogen bulbs, and UVB leak highest from CFL. The overall UVA/UVB leak was lowest from CFL shielded during the manufacturing process. In conclusion, patients with photosensitivity have choices depending on their relative risk from different UVL wavelength spectra. UVB exposure risk may be reduced the greatest by utilising CFL with manufacturer-provided shields.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19395458     DOI: 10.1177/0961203309103052

Source DB:  PubMed          Journal:  Lupus        ISSN: 0961-2033            Impact factor:   2.911


  3 in total

Review 1.  Rheumatic manifestations of skin disease.

Authors:  Jennie T Clarke; Victoria P Werth
Journal:  Curr Opin Rheumatol       Date:  2010-01       Impact factor: 5.006

2.  Comparative Analysis of Lighting Characteristics and Ultraviolet Emissions from Commercial Compact Fluorescent and Incandescent Lamps.

Authors:  Mahtab Azizi; Rostam Golmohammadi; Mohsen Aliabadi
Journal:  J Res Health Sci       Date:  2016

3.  UV-light exposure of insulin: pharmaceutical implications upon covalent insulin dityrosine dimerization and disulphide bond photolysis.

Authors:  Manuel Correia; Maria Teresa Neves-Petersen; Per Bendix Jeppesen; Søren Gregersen; Steffen B Petersen
Journal:  PLoS One       Date:  2012-12-05       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.