Modelling the mechanical response of elastin for arterial tissue.

Paul N Watton1, Yiannis Ventikos, Gerhard A Holzapfel.   

Abstract

We compare two constitutive models proposed to model the elastinous constituents of an artery. Holzapfel and Weizsäcker [1998. Biomechanical behavior of the arterial wall and its numerical characterization. Comput. Biol. Med. 28, 377-392] attribute a neo-Hookean response, i.e. Psi=c(I(1)-3)), to the elastin whilst Zulliger et al. [2004a. A strain energy function for arteries accounting for wall composition and structure. J. Biomech. 37, 989-1000] propose Psi=c(I(1)-3)(3/2). We analyse these constitutive models for two specific cases: (i) uniaxial extension of an elastinous sheet; (ii) inflation of a cylindrical elastinous membrane. For case (i) we illustrate the functional relationships between: (a) the Cauchy stress (CS) and the Green-Lagrange (GL) strain; (b) the tangent modulus (gradient of the CS-GL strain curve) and linearised strain. The predicted mechanical responses are compared with recent uniaxial extension tests on elastin [Gundiah, N., Ratcliffe, M.B., Pruitt, L.A., 2007. Determination of strain energy function for arterial elastin: experiments using histology and mechanical tests. J. Biomech. 40, 586-594; Lillie, M.A., Gosline, J.M., 2007a. Limits to the durability of arterial elastic tissue. Biomaterials 28, 2021-2031; 2007b. Mechanical properties of elastin along the thoracic aorta in the pig. J. Biomech. 40, 2214-2221]. The neo-Hookean model accurately predicts the mechanical response of a single elastin fibre. However, it is unable to accurately capture the mechanical response of arterial elastin, e.g. the initial toe region of arterial elastin (if it exists) or the gradual increase in modulus of arterial elastin that occurs as it is stretched. The alternative constitutive model (n=32) yields a nonlinear mechanical response that departs from recent uniaxial test data mentioned above, for the same stretch range. For case (ii) we illustrate the pressure-circumferential stretch relationships and the gradients of the pressure-circumferential stretch curves: significant qualitative differences are observed. For the neo-Hookean model, the gradient decreases rapidly to zero, however, for n=32, the gradient decreases more gradually to a constant value. We conclude that whilst the neo-Hookean model has limitations, it appears to capture more accurately the mechanical response of elastin.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19394942     DOI: 10.1016/j.jbiomech.2009.03.012

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  18 in total

Review 1.  Computational fluid dynamics in brain aneurysms.

Authors:  Daniel M Sforza; Christopher M Putman; Juan R Cebral
Journal:  Int J Numer Method Biomed Eng       Date:  2011-11-28       Impact factor: 2.747

2.  A theoretical and non-destructive experimental approach for direct inclusion of measured collagen orientation and recruitment into mechanical models of the artery wall.

Authors:  Michael R Hill; Xinjie Duan; Gregory A Gibson; Simon Watkins; Anne M Robertson
Journal:  J Biomech       Date:  2012-02-02       Impact factor: 2.712

3.  Determining the combined effect of the lymphatic valve leaflets and sinus on resistance to forward flow.

Authors:  John T Wilson; Raoul van Loon; Wei Wang; David C Zawieja; James E Moore
Journal:  J Biomech       Date:  2015-08-11       Impact factor: 2.712

4.  Effect of glucose on the biomechanical function of arterial elastin.

Authors:  Yunjie Wang; Shahrokh Zeinali-Davarani; Elaine C Davis; Yanhang Zhang
Journal:  J Mech Behav Biomed Mater       Date:  2015-05-14

5.  Differential histomechanical response of carotid artery in relation to species and region: mathematical description accounting for elastin and collagen anisotropy.

Authors:  Dimitrios P Sokolis; Sofia Sassani; Eleftherios P Kritharis; Sokrates Tsangaris
Journal:  Med Biol Eng Comput       Date:  2011-05-28       Impact factor: 2.602

6.  Computational modeling of the strength of the ascending thoracic aortic media tissue under physiologic biaxial loading conditions.

Authors:  Spandan Maiti; James R Thunes; Ronald N Fortunato; Thomas G Gleason; David A Vorp
Journal:  J Biomech       Date:  2020-06-14       Impact factor: 2.712

7.  Characterization of biaxial mechanical behavior of porcine aorta under gradual elastin degradation.

Authors:  Shahrokh Zeinali-Davarani; Ming-Jay Chow; Raphaël Turcotte; Yanhang Zhang
Journal:  Ann Biomed Eng       Date:  2013-01-08       Impact factor: 3.934

8.  On constitutive descriptors of the biaxial mechanical behaviour of human abdominal aorta and aneurysms.

Authors:  J Ferruzzi; D A Vorp; J D Humphrey
Journal:  J R Soc Interface       Date:  2010-07-21       Impact factor: 4.118

9.  Perspectives on biological growth and remodeling.

Authors:  D Ambrosi; G A Ateshian; E M Arruda; S C Cowin; J Dumais; A Goriely; G A Holzapfel; J D Humphrey; R Kemkemer; E Kuhl; J E Olberding; L A Taber; K Garikipati
Journal:  J Mech Phys Solids       Date:  2011-04-01       Impact factor: 5.471

10.  Growth and Remodeling of Load-Bearing Biological Soft Tissues.

Authors:  C J Cyron; J D Humphrey
Journal:  Meccanica       Date:  2016-06-27       Impact factor: 2.258