Literature DB >> 19394239

Preliminary liver dose estimation in the new facility for biomedical applications at the RA-3 reactor.

M Gadan1, V Crawley, S Thorp, M Miller.   

Abstract

As a part of the project concerning the irradiation of a section of the human liver left lobe, a preliminary estimation of the expected dose was performed. To obtain proper input values for the calculation, neutron flux and gamma dose rate characterization were carried out using adequate portions of cow or pig liver covered with demineralized water simulating the preservation solution. Irradiations were done inside a container specially designed to fulfill temperature preservation of the organ and a reproducible irradiation position (which will be of importance for future planification purposes). Implantable rhodium based self-powered neutron detectors were developed to obtain neutron flux profiles both external and internal. Implantation of SPND was done along the central longitudinal axis of the samples, where lowest flux is expected. Gamma dose rate was obtained using a neutron shielded graphite ionization chamber moved along external surfaces of the samples. The internal neutron profile resulted uniform enough to allow for a single and static irradiation of the liver. For dose estimation, irradiation condition was set in order to obtain a maximum of 15 Gy-eq in healthy tissue. Additionally, literature reported boron concentrations of 47 ppm in tumor and 8 ppm in healthy tissue and a more conservative relationship (30/10 ppm) were used. To make a conservative estimation of the dose the following considerations were done: i). Minimum measured neutron flux inside the sample (approximately 5 x 10(9) n cm-2 s-1) was considered to calculate dose in tumor. (ii). Maximum measured neutron flux (considering both internal as external profiles) was used to calculate dose in healthy tissue (approximately 8.7 x 10(9) n cm-2 s-1). (iii). Maximum measured gamma dose rate (approximately 13.5 Gy h-1) was considered for both tumor and healthy tissue. Tumor tissue dose was approximately 69 Gy-eq for 47 ppm of (10)B and approximately 42 Gy-eq for 30 ppm, for a maximum dose of 15 Gy-eq in healthy tissue. As can be seen from these results, even for the most conservative case, minimum tumor dose will be acceptable from the treatment point of view, which shows that the irradiation conditions at this facility have quite good characteristics for the proposed irradiation.

Entities:  

Mesh:

Year:  2009        PMID: 19394239     DOI: 10.1016/j.apradiso.2009.03.051

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  1 in total

1.  Experimental set up for the irradiation of biological samples and nuclear track detectors with UV C.

Authors:  Agustina Mariana Portu; Andrés Eugenio Rossini; Mario Alberto Gadan; Omar Alberto Bernaola; Silvia Inés Thorp; Paula Curotto; Emiliano César Cayetano Pozzi; Rómulo Luis Cabrini; Gisela Saint Martin
Journal:  Rep Pract Oncol Radiother       Date:  2014-11-04
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.