Literature DB >> 19393140

Drug-eluting stenting: the case for post-dilation.

Enrico Romagnoli1, Giuseppe M Sangiorgi, John Cosgrave, Edouard Guillet, Antonio Colombo.   

Abstract

In clinical practice, adequate stent deployment has an important effect on immediate and long-term results after percutaneous coronary interventions. In particular, suboptimal or incomplete stent expansion is associated with increased restenosis and target vessel revascularization rates and, especially with drug-eluting stents (DES), might also predispose to stent thrombosis. Notwithstanding the significant improvement in technique and materials in the last decade, adjunctive high-pressure balloon dilation is still necessary to improve the minimum stent area and the uniform volumetric stent expansion in a majority of the cases. Indeed, in the published reports, the incidence of incomplete stent deployment ranges from 20% to 30% of cases, but it is significantly higher in trials in which stent expansion was assessed by intravascular ultrasound. Although there are not enough randomized studies about this topic, data from published reports continue to support the use of proper post-dilation in the majority of patients undergoing both bare-metal stent and DES implantation. This review will summarize the different anatomical, clinical, and device-related variables for increased risk of suboptimal stent delivery, highlighting the importance of adequate high-pressure post-dilation to obtain optimal stent expansion to positively affect stent thrombosis and restenosis.

Entities:  

Mesh:

Year:  2008        PMID: 19393140     DOI: 10.1016/j.jcin.2007.10.005

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  13 in total

1.  Interventional cardiology: does stent overlap make a difference to clinical outcome?

Authors:  Antonio Colombo; Rasha Al-Lamee
Journal:  Nat Rev Cardiol       Date:  2010-07       Impact factor: 32.419

2.  Expert Opinion: Optimising Stent Deployment in Contemporary Practice: The Role of Intracoronary Imaging and Non-compliant Balloons.

Authors:  Ashok Seth; Sajal Gupta; Vivudh Pratap Singh; Vijay Kumar
Journal:  Interv Cardiol       Date:  2017-09

3.  Effect of stent inflation pressure and post-dilatation on the outcome of coronary artery intervention. A report of more than 90,000 stent implantations.

Authors:  Ole Fröbert; Giovanna Sarno; Stefan K James; Nawsad Saleh; Bo Lagerqvist
Journal:  PLoS One       Date:  2013-02-13       Impact factor: 3.240

4.  What is The Next Step When a Non-Compliant Balloon Does Not Pass through a Freshly Deployed Stent?

Authors:  Arash Gholoobi
Journal:  J Tehran Heart Cent       Date:  2014

5.  Stent Optimization Using Adjunctive Balloon Dilatation in the Era of Second-Generation Drug-Eluting Stents.

Authors:  Min Chul Kim; Ju Han Kim
Journal:  Korean Circ J       Date:  2017-09-11       Impact factor: 3.243

6.  Effect of Adjunct Balloon Dilation after Long Everolimus-eluting Stent Deployment on Major Adverse Cardiac Events.

Authors:  Sung-Jin Hong; Chul-Min Ahn; Dong-Ho Shin; Jung-Sun Kim; Byeong-Keuk Kim; Young-Guk Ko; Donghoon Choi; Ae-Young Her; Yong Hoon Kim; Yangsoo Jang; Myeong-Ki Hong
Journal:  Korean Circ J       Date:  2017-09-18       Impact factor: 3.243

7.  The Clinical and Angiographic Outcomes of Postdilation after Percutaneous Coronary Intervention in Patients with Acute Coronary Syndrome: A Systematic Review and Meta-Analysis.

Authors:  Yan Li; Xiying Liang; Wenjiao Zhang; Xuan Qiao; Zhilu Wang
Journal:  J Interv Cardiol       Date:  2021-04-09       Impact factor: 2.279

8.  Changes of plasma B-type natriuretic peptide levels after high-pressure post-dilation following coronary stent deployment.

Authors:  Gang-Yong Wu; Gang-Jun Zong; Jing-Kai Chen; Yang Xia; Man-Qing Chen; Xiao Wang; Xiao-Ying Wang; Lu-Lu Wang; Tian-Xiao Wang
Journal:  PLoS One       Date:  2013-12-06       Impact factor: 3.240

9.  Efficacy of non-compliant balloon post-dilation in optimization of contemporary stents: A digital stent enhancement study.

Authors:  Jaya Chandrasekhar; Christopher Allada; Simon O'Connor; Moyazur Rahman; Bruce Shadbolt; Ahmad Farshid
Journal:  Int J Cardiol Heart Vessel       Date:  2014-03-19

10.  Additional postdilatation using noncompliant balloons after everolimus-eluting stent implantation: Results of the PRESS trial.

Authors:  Gyung-Min Park; Jae-Hwan Lee; Si Wan Choi; Jin-Ok Jeong; Eun-Seok Shin; Jang-Whan Bae; Hyuck-Jun Yoon; Kyung Tae Jung; Ju Yeol Baek; Woong Gil Choi; Rak Kyeong Choi; Sung-Ho Her; Jin Bae Lee; Jon Suh; Jae Beom Lee; Se-Whan Lee; In-Ho Chae; So-Yeon Choi; In-Whan Seong
Journal:  Clin Cardiol       Date:  2020-03-16       Impact factor: 2.882

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.