Literature DB >> 19392604

Surface-based facial scan registration in neuronavigation procedures: a clinical study.

Reuben R Shamir1, Moti Freiman, Leo Joskowicz, Sergey Spektor, Yigal Shoshan.   

Abstract

OBJECT: Surface-based registration (SBR) with facial surface scans has been proposed as an alternative for the commonly used fiducial-based registration in image-guided neurosurgery. Recent studies comparing the accuracy of SBR and fiducial-based registration have been based on a few targets located on the head surface rather than inside the brain and have yielded contradictory conclusions. Moreover, no visual feedback is provided with either method to inform the surgeon about the estimated target registration error (TRE) at various target locations. The goals in the present study were: 1) to quantify the SBR error in a clinical setup, 2) to estimate the targeting error for many target locations inside the brain, and 3) to create a map of the estimated TRE values superimposed on a patient's head image.
METHODS: The authors randomly selected 12 patients (8 supine and 4 in a lateral position) who underwent neurosurgery with a commercial navigation system. Intraoperatively, scans of the patients' faces were acquired using a fast 3D surface scanner and aligned with their preoperative MR or CT head image. In the laboratory, the SBR accuracy was measured on the facial zone and estimated at various intracranial target locations. Contours related to different TREs were superimposed on the patient's head image and informed the surgeon about the expected anisotropic error distribution.
RESULTS: The mean surface registration error in the face zone was 0.9 +/- 0.35 mm. The mean estimated TREs for targets located 60, 105, and 150 mm from the facial surface were 2.0, 3.2, and 4.5 mm, respectively. There was no difference in the estimated TRE between the lateral and supine positions. The entire registration procedure, including positioning of the scanner, surface data acquisition, and the registration computation usually required < 5 minutes.
CONCLUSIONS: Surface-based registration accuracy is better in the face and frontal zones, and error increases as the target location lies further from the face. Visualization of the anisotropic TRE distribution may help the surgeon to make clinical decisions. The observed and estimated accuracies and the intraoperative registration time show that SBR using the fast surface scanner is practical and feasible in a clinical setup.

Entities:  

Mesh:

Year:  2009        PMID: 19392604     DOI: 10.3171/2009.3.JNS081457

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  13 in total

1.  Design and evaluation of an optically-tracked single-CCD laser range scanner.

Authors:  Thomas S Pheiffer; Amber L Simpson; Brian Lennon; Reid C Thompson; Michael I Miga
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

2.  Surgical treatment of distal anterior cerebral artery aneurysms aided by electromagnetic navigation CT angiography.

Authors:  Elvis J Hermann; Ioannis Petrakakis; Friedrich Götz; Götz Lütjens; Josef Lang; Makoto Nakamura; Joachim K Krauss
Journal:  Neurosurg Rev       Date:  2015-02-10       Impact factor: 3.042

3.  Intraoperative navigation in complex head and neck resections: indications and limits.

Authors:  S Catanzaro; C Copelli; A Manfuso; K Tewfik; N Pederneschi; L Cassano; R Cocchi
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-09-22       Impact factor: 2.924

4.  The role of automatic computer-aided surgical trajectory planning in improving the expected safety of stereotactic neurosurgery.

Authors:  M Trope; R R Shamir; L Joskowicz; Z Medress; G Rosenthal; A Mayer; N Levin; A Bick; Y Shoshan
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-11-20       Impact factor: 2.924

5.  An automatic markerless registration method for neurosurgical robotics based on an optical camera.

Authors:  Fanle Meng; Fangwen Zhai; Bowei Zeng; Hui Ding; Guangzhi Wang
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-11-03       Impact factor: 2.924

6.  Intraoperative patient registration using volumetric true 3D ultrasound without fiducials.

Authors:  Songbai Ji; David W Roberts; Alex Hartov; Keith D Paulsen
Journal:  Med Phys       Date:  2012-12       Impact factor: 4.071

7.  Near Real-Time Computer Assisted Surgery for Brain Shift Correction Using Biomechanical Models.

Authors:  Kay Sun; Thomas S Pheiffer; Amber L Simpson; Jared A Weis; Reid C Thompson; Michael I Miga
Journal:  IEEE J Transl Eng Health Med       Date:  2014-04-30       Impact factor: 3.316

8.  Automatic deformable surface registration for medical applications by radial basis function-based robust point-matching.

Authors:  Youngjun Kim; Yong Hum Na; Lei Xing; Rena Lee; Sehyung Park
Journal:  Comput Biol Med       Date:  2016-08-11       Impact factor: 4.589

9.  Comparison study of intraoperative surface acquisition methods for surgical navigation.

Authors:  Amber L Simpson; Jessica Burgner; Courtenay L Glisson; S Duke Herrell; Burton Ma; Thomas S Pheiffer; Robert J Webster; Michael I Miga
Journal:  IEEE Trans Biomed Eng       Date:  2012-08-23       Impact factor: 4.538

10.  Validation of a novel method for canine eruption assessment in unilateral cleft lip and palate patients.

Authors:  Khalid Alqahtani; Eman Shaheen; Sohaib Shujaat; Mostafa EzEldeen; Titiaan Dormaar; Maria Cadenas de Llano-Pérula; Constantinus Politis; Reinhilde Jacobs
Journal:  Clin Exp Dent Res       Date:  2021-01-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.