Literature DB >> 19389904

Peripherally inserted central catheter placement with the sonic flashlight: initial clinical trial by nurses.

David Wang1, Nikhil Amesur, Gaurav Shukla, Angela Bayless, David Weiser, Adam Scharl, Derek Mockel, Christopher Banks, Bernadette Mandella, Roberta Klatzky, George Stetten.   

Abstract

OBJECTIVE: We describe a case series constituting the first clinical trial by intravenous (IV) team nurses using the sonic flashlight (SF) for ultrasound guidance of peripherally inserted central catheter (PICC) placement.
METHODS: Two IV team nurses with more than 10 years of experience with placing PICCs and 3 to 6 years of experience with ultrasound attempted to place PICCs under ultrasound guidance in patients requiring long-term IV access. One of two methods of ultrasound guidance was used: conventional ultrasound (CUS; 60 patients) or a new device called the SF (44 patients). The number of needle punctures required to gain IV access was recorded for each patient.
RESULTS: In both methods, 87% of the cases resulted in successful venous access on the first attempt. The average number of needle sticks per patient was 1.18 for SF-guided procedures compared with 1.20 for CUS-guided procedures. No significant difference was found in the distribution of the number of attempts between the two methods. Anecdotal comments by the nurses indicated the comparative ease of use of the SF display, although the relatively small scale of the SF image compared with the CUS image was also noted.
CONCLUSIONS: We have shown that the SF is a safe and effective device for guidance of PICC placement in the hands of experienced IV team nurses. The advantage of placing the ultrasound image at its actual location must be balanced against the relatively small scale of the SF image.

Entities:  

Mesh:

Year:  2009        PMID: 19389904      PMCID: PMC2869215          DOI: 10.7863/jum.2009.28.5.651

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  12 in total

1.  Overlaying ultrasonographic images on direct vision.

Authors:  G D Stetten; V S Chib
Journal:  J Ultrasound Med       Date:  2001-03       Impact factor: 2.153

Review 2.  Nurse-driven interventional technology. A cost and benefit perspective.

Authors:  T Royer
Journal:  J Infus Nurs       Date:  2001 Sep-Oct

3.  Vascular access: comparison of US guidance with the sonic flashlight and conventional US in phantoms.

Authors:  Wilson M Chang; Nikhil B Amesur; Roberta L Klatzky; Albert B Zajko; George D Stetten
Journal:  Radiology       Date:  2006-12       Impact factor: 11.105

4.  Psychophysical evaluation of in-situ ultrasound visualization.

Authors:  Bing Wu; Roberta L Klatzky; Damion Shelton; George D Stetten
Journal:  IEEE Trans Vis Comput Graph       Date:  2005 Nov-Dec       Impact factor: 4.579

5.  Cost losses associated with the "PICC, stick, and run team" concept.

Authors:  Sally Hornsby; Kate Matter; Beth Beets; Sue Casey; Kathy Kokotis
Journal:  J Infus Nurs       Date:  2005 Jan-Feb

6.  The efficacy of upper arm placement of peripherally inserted central catheters using bedside ultrasound and microintroducer technique.

Authors:  Inez Nichols; James P Humphrey
Journal:  J Infus Nurs       Date:  2008 May-Jun

7.  Sonographically guided placement of peripherally inserted central venous catheters: review of 355 procedures.

Authors:  C T Sofocleous; I Schur; S G Cooper; J C Quintas; L Brody; R Shelin
Journal:  AJR Am J Roentgenol       Date:  1998-06       Impact factor: 3.959

8.  Intuitive intraoperative ultrasound guidance using the Sonic Flashlight: a novel ultrasound display system.

Authors:  Wilson M Chang; Michael B Horowitz; George D Stetten
Journal:  Neurosurgery       Date:  2005-04       Impact factor: 4.654

9.  Interventional radiologic placement of peripherally inserted central catheters.

Authors:  J F Cardella; P S Fox; J B Lawler
Journal:  J Vasc Interv Radiol       Date:  1993 Sep-Oct       Impact factor: 3.464

10.  Guidance of retrobulbar injection with real-time tomographic reflection.

Authors:  Wilson M Chang; George D Stetten; Louis A Lobes; Damion M Shelton; Robert J Tamburo
Journal:  J Ultrasound Med       Date:  2002-10       Impact factor: 2.153

View more
  5 in total

1.  Visualizing 3D objects from 2D cross sectional images displayed in-situ versus ex-situ.

Authors:  Bing Wu; Roberta L Klatzky; George Stetten
Journal:  J Exp Psychol Appl       Date:  2010-03

Review 2.  Assistive technology for ultrasound-guided central venous catheter placement.

Authors:  Mohammad Ikhsan; Kok Kiong Tan; Andi Sudjana Putra
Journal:  J Med Ultrason (2001)       Date:  2017-04-19       Impact factor: 1.314

3.  Mental visualization of objects from cross-sectional images.

Authors:  Bing Wu; Roberta L Klatzky; George D Stetten
Journal:  Cognition       Date:  2012-01-02

Review 4.  The disembodied eye: consequences of displacing perception from action.

Authors:  Roberta L Klatzky; Bing Wu; George Stetten
Journal:  Vision Res       Date:  2010-08-27       Impact factor: 1.886

5.  Prevention of catheter tip malposition with an ultrasound-guided finger-pressure method to block the internal jugular vein during PICC placement: a meta-analysis.

Authors:  Yan Zheng; Hua-Jing Zhou; Nian Tao; Yun Tian; Shu-Wen Qin; Bi-Yong Qin; Yu Xia
Journal:  Wideochir Inne Tech Maloinwazyjne       Date:  2022-04-04       Impact factor: 1.627

  5 in total