Literature DB >> 19389690

Regularized estimation of retinal vascular oxygen tension from phosphorescence images.

Isa Yildirim1, Rashid Ansari, Justin Wanek, Imam Samil Yetik, Mahnaz Shahidi.   

Abstract

The level of retinal oxygenation is potentially an important cue to the onset or presence of some common retinal diseases. An improved method for assessing oxygen tension in retinal blood vessels from phosphorescence lifetime imaging data is reported in this paper. The optimum estimate for phosphorescence lifetime and oxygen tension is obtained by regularizing the least-squares (LS) method. The estimation method is implemented with an iterative algorithm to minimize a regularized LS cost function. The effectiveness of the proposed method is demonstrated by applying it to simulated data as well as image data acquired from rat retinas. The method is shown to yield estimates that are robust to noise and whose variance is lower than that obtained with the classical LS method.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19389690      PMCID: PMC2885291          DOI: 10.1109/TBME.2009.2020505

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  11 in total

1.  Edge-preserving tomographic reconstruction with nonlocal regularization.

Authors:  Daniel F Yu; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2002-02       Impact factor: 10.048

2.  Fluorescence lifetime imaging.

Authors:  J R Lakowicz; H Szmacinski; K Nowaczyk; K W Berndt; M Johnson
Journal:  Anal Biochem       Date:  1992-05-01       Impact factor: 3.365

3.  A segmentation-based regularization term for image deconvolution.

Authors:  Max Mignotte
Journal:  IEEE Trans Image Process       Date:  2006-07       Impact factor: 10.856

4.  Methods for choosing the regularization parameter and estimating the noise variance in image restoration and their relation.

Authors:  N P Galatsanos; A K Katsaggelos
Journal:  IEEE Trans Image Process       Date:  1992       Impact factor: 10.856

5.  General choice of the regularization functional in regularized image restoration.

Authors:  M G Kang; A K Katsaggelos
Journal:  IEEE Trans Image Process       Date:  1995       Impact factor: 10.856

6.  Wavelet domain image restoration with adaptive edge-preserving regularization.

Authors:  M Belge; M E Kilmer; E L Miller
Journal:  IEEE Trans Image Process       Date:  2000       Impact factor: 10.856

7.  Intraretinal oxygen distribution in the rat with graded systemic hyperoxia and hypercapnia.

Authors:  D Y Yu; S J Cringle; V Alder; E N Su
Journal:  Invest Ophthalmol Vis Sci       Date:  1999-08       Impact factor: 4.799

8.  A method for chorioretinal oxygen tension measurement.

Authors:  Mahnaz Shahidi; Akbar Shakoor; Norman P Blair; Marek Mori; Ross D Shonat
Journal:  Curr Eye Res       Date:  2006-04       Impact factor: 2.424

9.  Three-dimensional mapping of chorioretinal vascular oxygen tension in the rat.

Authors:  Mahnaz Shahidi; Justin Wanek; Norman P Blair; Marek Mori
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-09-29       Impact factor: 4.799

10.  Oxygen tension imaging in the mouse retina.

Authors:  Ross D Shonat; Amanda C Kight
Journal:  Ann Biomed Eng       Date:  2003-10       Impact factor: 3.934

View more
  2 in total

1.  Direct regularized estimation of retinal vascular oxygen tension based on an experimental model.

Authors:  Isa Yildirim; Rashid Ansari; I Samil Yetik; Mahnaz Shahidi
Journal:  Ann Biomed Eng       Date:  2013-06-04       Impact factor: 3.934

2.  A fast regularized least-squares method for retinal vascular oxygen tension estimation using a phosphorescence lifetime imaging model.

Authors:  Gokhan Gunay; Isa Yildirim
Journal:  Biomed Eng Online       Date:  2013-10-16       Impact factor: 2.819

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.