Literature DB >> 19387157

A new diagnostic algorithm for early prediction of vascular compromise in 208 microsurgical flaps using tissue oxygen saturation measurements.

Alex Keller1.   

Abstract

The purpose of the study was to evaluate the detection of vascular complications earlier than clinical evidence using a noninvasive near-infrared tissue oximeter monitor. Early detection of circulatory compromise allows for earlier re-exploration and better outcomes. The monitoring method studied was the ViOptix T.Ox Tissue Oximeter (ViOptix Inc., Fremont, CA). The device uses an optical tissue characterization based on measuring scattering and absorption of near infrared light. Tissue oxygen saturation and its derivates were evaluated as candidates for a more sensitive algorithm to predict vascular flap complications. Criteria studied in various combinations were the absolute value of tissue oxygen saturation (StO2), the amount of its change (DeltaStO2) and the rate of its change (DeltaStO2/Deltat). There were 208 monitored breast flaps in 145 patients (62 bilateral and 83 unilateral). In 1 patient, 2 flaps were used to make a single breast. Patients were monitored intraoperatively and postoperatively for 36 hours. No flap being monitored was lost. Among the 208 flaps monitored, 5 patients exhibited complications that were predicted by the tissue oximeter before clinical signs were evident. If blood flow was completely occluded by either venous or arterial thrombosis, the tissue oximeter provided information that enabled diagnosis to be made in about 1 hour. The drop rate indicator DeltaStO2/Deltat, when it is equal to or greater than 20% per hour sustained more than 30 minutes predicted vascular complications. The use of the new diagnostic algorithm with the T.Ox Tissue Oximeter monitor was successful in predicting flap complication within 1 hour of the onset of the occlusive event with a high diagnostic accuracy in the 208 flap procedures.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19387157     DOI: 10.1097/SAP.0b013e3181a47ce8

Source DB:  PubMed          Journal:  Ann Plast Surg        ISSN: 0148-7043            Impact factor:   1.539


  25 in total

1.  Evaluation of hyperspectral imaging (HSI) for the measurement of ischemic conditioning effects of the gastric conduit during esophagectomy.

Authors:  Hannes Köhler; Boris Jansen-Winkeln; Marianne Maktabi; Manuel Barberio; Jonathan Takoh; Nico Holfert; Yusef Moulla; Stefan Niebisch; Michele Diana; Thomas Neumuth; Sebastian M Rabe; Claire Chalopin; Andreas Melzer; Ines Gockel
Journal:  Surg Endosc       Date:  2019-01-23       Impact factor: 4.584

2.  Clamping renal artery alone produces less ischemic damage compared to clamping renal artery and vein together in two animal models: near-infrared tissue oximetry and quantitation of 8-isoprostane levels.

Authors:  J L Colli; Z Wang; N Johnsen; L Grossman; B R Lee
Journal:  Int Urol Nephrol       Date:  2012-09-30       Impact factor: 2.370

3.  [Hyperspectral imaging of gastrointestinal anastomoses].

Authors:  B Jansen-Winkeln; M Maktabi; J P Takoh; S M Rabe; M Barberio; H Köhler; T Neumuth; A Melzer; C Chalopin; I Gockel
Journal:  Chirurg       Date:  2018-09       Impact factor: 0.955

4.  Intraoperative prediction of postoperative flap outcome using the near-infrared fluorophore methylene blue.

Authors:  Yoshitomo Ashitate; Bernard T Lee; Rita G Laurence; Elaine Lunsford; Merlijn Hutteman; Rafiou Oketokoun; Hak Soo Choi; John V Frangioni
Journal:  Ann Plast Surg       Date:  2013-03       Impact factor: 1.539

Review 5.  Soft tissue management of war wounds to the foot and ankle.

Authors:  Martin F Baechler; Adam T Groth; Leon J Nesti; Barry D Martin
Journal:  Foot Ankle Clin       Date:  2010-03       Impact factor: 1.653

Review 6.  Free Tissue Breast Reconstruction.

Authors:  Rami Dibbs; Jeff Trost; Valerie DeGregorio; Shayan Izaddoost
Journal:  Semin Plast Surg       Date:  2019-03-08       Impact factor: 2.314

7.  First-in-human pilot study of a spatial frequency domain oxygenation imaging system.

Authors:  Sylvain Gioux; Amaan Mazhar; Bernard T Lee; Samuel J Lin; Adam M Tobias; David J Cuccia; Alan Stockdale; Rafiou Oketokoun; Yoshitomo Ashitate; Edward Kelly; Maxwell Weinmann; Nicholas J Durr; Lorissa A Moffitt; Anthony J Durkin; Bruce J Tromberg; John V Frangioni
Journal:  J Biomed Opt       Date:  2011-08       Impact factor: 3.170

8.  A novel pilot study using spatial frequency domain imaging to assess oxygenation of perforator flaps during reconstructive breast surgery.

Authors:  John T Nguyen; Samuel J Lin; Adam M Tobias; Sylvain Gioux; Amaan Mazhar; David J Cuccia; Yoshitomo Ashitate; Alan Stockdale; Rafiou Oketokoun; Nicholas J Durr; Lorissa A Moffitt; Anthony J Durkin; Bruce J Tromberg; John V Frangioni; Bernard T Lee
Journal:  Ann Plast Surg       Date:  2013-09       Impact factor: 1.539

Review 9.  Evaluation of skin viability in nipple sparing mastectomy (NSM).

Authors:  Michael R Zenn
Journal:  Gland Surg       Date:  2018-06

10.  Laser Doppler Flowmetry to Differentiate Arterial From Venous Occlusion in Free Tissue Transfer.

Authors:  Emre Gazyakan; Huang-Kai Kao; Ming-Huei Cheng; Holger Engel
Journal:  Plast Surg (Oakv)       Date:  2019-09-19       Impact factor: 0.947

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.