BACKGROUND: The recommended thickness of the graft lamella in Descemet's stripping automated endothelial keratoplasty (DSAEK) is 120 - 180 microm. To adjust for the large variation in central corneal thickness (CCT) of eye bank donor corneas, microkeratome plates of different heights are available. The aim of this study was to evaluate the lamella thickness predictability of different keratome plates in a clinical routine setting.
METHODS: In a prospective study of 60 consecutive DSAEK procedures, CCT was measured with a 50 MHz ultrasound pachymeter after meticulous epithelium removal immediately before and after lamella creation. Selected plate thickness was 300, 350, or 400 micro, respectively. Cutting depth was calculated by subtracting the remaining CCT of the deep lamella after the cut from the initial CCT before the cut.
RESULTS: The mean (+/- SD) cutting depth was 320 +/- 45 microm with the Amadeus 350 keratome, 317 +/- 48 microm with the Moria 300 keratome, 388 +/- 58 microm with the Moria 350 keratome and 467 +/- 94 microm with the Moria 400 keratome. Neither the duration nor the type of donor preservation had an effect on the accuracy of the cutting depth.
CONCLUSION: The mean cutting depth for the DSAEK keratomes is more accurate than the cutting depth of the same keratome heads designed for LASIK. This might be due to the fact that DSAEK lamellas were cut after complete epithelial removal. Despite the accurate mean cutting accuracy, there is a substantial variation between individual cuts which have to be taken into consideration.

Entities:  

Mesh:

Year:  2009        PMID: 19384772     DOI: 10.1055/s-0028-1109243

Source DB:  PubMed          Journal:  Klin Monbl Augenheilkd        ISSN: 0023-2165            Impact factor:   0.700


  5 in total

Review 1.  [Complications of Descemet Stripping Automated Endothelial Keratoplasty (DSAEK)].

Authors:  M A Thiel; F Bochmann; A Schmittinger-Zirm; P B Bänninger; M K Schmid; C Kaufmann
Journal:  Ophthalmologe       Date:  2015-12       Impact factor: 1.059

2.  Analysis of posterior donor corneal parameters 1 year after Descemet stripping automated endothelial keratoplasty (DSAEK) triple procedure.

Authors:  Marco Lombardo; Mark A Terry; Giuseppe Lombardo; David D Boozer; Sebastiano Serrao; Pietro Ducoli
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-01-29       Impact factor: 3.117

Review 3.  [Perspectives of posterior lamellar keratoplasty. In search of the perfect lamella].

Authors:  S Heinzelmann; P Maier; T Reinhard
Journal:  Ophthalmologe       Date:  2011-09       Impact factor: 1.059

4.  Ophthalmic transplantology: anterior segment of the eye - part I.

Authors:  Małgorzata Nita; Barbara Strzałka-Mrozik; Andrzej Grzybowski; Wanda Romaniuk; Urszula Mazurek
Journal:  Med Sci Monit       Date:  2012-05

5.  Constructing a Novel Three-Dimensional Biomimetic Corneal Endothelium Graft by Culturing Corneal Endothelium Cells on Compressed Collagen Gels.

Authors:  Yu-Jie Cen; Yun Feng
Journal:  Chin Med J (Engl)       Date:  2018-07-20       Impact factor: 2.628

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.