The temperature changes in the pulp chamber during cavity preparation with the Er:YAG laser using a very short pulse.

Silvana Jukić Krmek1, Ivana Miletic, Paris Simeon, Goranka Prpić Mehicić, Ivica Anić, Berislav Radisić.   

Abstract

OBJECTIVE: The aim of this study was to examine the temperature changes in the pulp chamber during cavity preparation with the Er:YAG laser (2940 nm) with a very short pulse (VSP).
MATERIALS AND METHODS: Nine groups of 10 intact molars each were used. One root of each sample was amputated and a thermocouple was inserted into the chamber. Class V cavity preparation in enamel was performed, and then preparation was performed in dentine. The enamel was lased with 400, 360, and 320 mJ in contact mode using a VSP with a duration of 100 microsec. The diameter of the fiber tip was 950 microm. Frequencies of 10, 12, and 15 Hz were used, and the total time of irradiation was 10 sec. The dentine was irradiated with 340, 280, and 200 mJ at 10, 8, and 5 Hz for 7 sec. Cooling was done with a water spray (73 psi and 50 mL/min). The differences were tested by MANOVA and the Bonferroni post hoc test.
RESULTS: The highest rise in temperature in the pulp was achieved after enamel irradiation with 400 mJ and 15 Hz (1.99 +/- 0.28 degrees C), and the lowest was after irradiation with 320 mJ and 10 Hz (0.70 +/- 0.18 degrees C). In dentine the highest temperature increase was achieved with 340 mJ and 10 Hz (1.37 +/- 0.42 degrees C), and the lowest was with 200 mJ and 5 Hz (0.43 +/- 0.18 degrees C). Two-way analysis of both enamel and dentine showed that the influence of energy on temperature increase was stronger than that of frequency.
CONCLUSION: Cavity preparation with an Er:YAG laser using VSP mode in vitro did not cause significant increases in temperature in the pulp chamber of human molars.

Entities:  

Mesh:

Year:  2009        PMID: 19382839     DOI: 10.1089/pho.2008.2247

Source DB:  PubMed          Journal:  Photomed Laser Surg        ISSN: 1549-5418            Impact factor:   2.796


  4 in total

1.  Comparison of the Er,Cr:YSGG laser with a chemical vapour deposition bur and conventional techniques for cavity preparation: a microleakage study.

Authors:  A Rüya Yazici; Zeren Yıldırım; Sibel A Antonson; Evren Kilinc; Daniele Koch; Donald E Antonson; Berrin Dayangaç; Gül Ozgünaltay
Journal:  Lasers Med Sci       Date:  2010-09-15       Impact factor: 3.161

2.  A three-dimensional evaluation of microleakage of class V cavities prepared by the very short pulse mode of the erbium:yttrium-aluminium-garnet laser.

Authors:  Silvana Jukić Krmek; Ivana Bogdan; Paris Simeon; Goranka Prpić Mehicić; Davor Katanec; Ivica Anić
Journal:  Lasers Med Sci       Date:  2009-07-11       Impact factor: 3.161

Review 3.  Laser restorative dentistry in children and adolescents.

Authors:  G Olivi; M D Genovese
Journal:  Eur Arch Paediatr Dent       Date:  2011-04

4.  Evaluation of temperature rise and efficacy of cavity disinfection with diode laser: An in vivo study.

Authors:  Sakshi Jain; Shivani Mathur; Pulkit Jhingan; Vinod Sachdev
Journal:  J Conserv Dent       Date:  2020-08-20
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.