Literature DB >> 19381810

In vitro, time-resolved PIV comparison of the effect of stent design on wall shear stress.

John Charonko1, Satyaprakash Karri, Jaime Schmieg, Santosh Prabhu, Pavlos Vlachos.   

Abstract

The effect of stent design on wall shear stress (WSS) and oscillatory shear index (OSI) was studied in vitro using time-resolved digital particle image velocimetry (DPIV). Four drug-eluting stents [XIENCE V (Abbott Vascular), TAXUS Liberté (Boston Scientific), Endeavor (Medtronic), and Cypher (J&J Cordis)] and a bare-metal stent [VISION (Abbott Vascular)] were implanted into compliant vessel models, and the flow was measured in physiologically accurate coronary conditions featuring reversal and realistic offsets between pressure and flowrate. DPIV measurements were made at three locations under two different flow rates (resting: Re = 160, f = 70 bpm and exercise: Re = 300, f = 120 bpm). It was observed that design substantially affected the WSS experienced at the vessel walls. Averaged values between struts ranged from 2.05 dynes/cm(2) (Cypher) to 8.52 dynes/cm(2) (XIENCE V) in resting conditions, and from 3.72 dynes/cm(2) (Cypher) to 14.66 dynes/cm(2) (VISION) for the exercise state. Within the stent, the WSS dropped and the OSI increased immediately distal to each strut. In addition, an inverse correlation between average WSS and OSI existed. Comparisons with recently published results from animal studies show strong correlation between the measured WSS and observed endothelial cell coverage. These results suggest the importance of stent design on the WSS experienced by endothelial cells in coronary arteries.

Entities:  

Mesh:

Year:  2009        PMID: 19381810     DOI: 10.1007/s10439-009-9697-y

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  7 in total

1.  Parametric Optimization of 3D Printed Hydrogel-Based Cardiovascular Stent.

Authors:  Krishna Veerubhotla; Yugyung Lee; Chi H Lee
Journal:  Pharm Res       Date:  2021-05-10       Impact factor: 4.200

2.  The stentable in vitro artery: an instrumented platform for endovascular device development and optimization.

Authors:  Elizabeth E Antoine; François P Cornat; Abdul I Barakat
Journal:  J R Soc Interface       Date:  2016-12       Impact factor: 4.118

Review 3.  3D Printing for Cardiovascular Applications: From End-to-End Processes to Emerging Developments.

Authors:  Ramtin Gharleghi; Claire A Dessalles; Ronil Lal; Sinead McCraith; Kiran Sarathy; Nigel Jepson; James Otton; Abdul I Barakat; Susann Beier
Journal:  Ann Biomed Eng       Date:  2021-05-17       Impact factor: 3.934

4.  Effect of pannus formation on the prosthetic heart valve: In vitro demonstration using particle image velocimetry.

Authors:  Hojin Ha; Hyun Jung Koo; Hyung Kyu Huh; Guk Bae Kim; Jihoon Kweon; Namkug Kim; Young-Hak Kim; Joon-Won Kang; Tae-Hwan Lim; Jae-Kwan Song; Sang Joon Lee; Dong Hyun Yang
Journal:  PLoS One       Date:  2018-06-28       Impact factor: 3.240

5.  Determining Haemodynamic Wall Shear Stress in the Rabbit Aorta In Vivo Using Contrast-Enhanced Ultrasound Image Velocimetry.

Authors:  K Riemer; E M Rowland; C H Leow; M X Tang; P D Weinberg
Journal:  Ann Biomed Eng       Date:  2020-03-04       Impact factor: 3.934

6.  Endoleak Assessment Using Computational Fluid Dynamics and Image Processing Methods in Stented Abdominal Aortic Aneurysm Models.

Authors:  Yueh-Hsun Lu; Karthick Mani; Bivas Panigrahi; Wen-Tang Hsu; Chia-Yuan Chen
Journal:  Comput Math Methods Med       Date:  2016-08-31       Impact factor: 2.238

7.  Evaluation of a Desktop 3D Printed Rigid Refractive-Indexed-Matched Flow Phantom for PIV Measurements on Cerebral Aneurysms.

Authors:  W H Ho; I J Tshimanga; M N Ngoepe; M C Jermy; P H Geoghegan
Journal:  Cardiovasc Eng Technol       Date:  2019-12-09       Impact factor: 2.495